bioRxivNeurosciencePreprint
A portable cortical evoked potential operant conditioning system (C-EPOCS): System development
Disha GuptaiD, Jodi A. BrangaccioiD, Helia MojtabaviiD, N. Jeremy HilliD
Abstract
This study presents customizations and evaluations aimed at adapting the Cortical-Evoked Potential Operant Conditioning System (C-EPOCS) into a portable, user-friendly platform for real-time neurofeedback applications. A primary goal was to simplify the component-heavy setup by integrating electroencephalography (EEG) and electromyography (EMG) data acquisition into a single system--while still supporting cortical and muscle response assessment and real-time feedback. One key limitation of portable biosignal acquisition systems is their typically lower sampling rates (e.g., 300-600 Hz) compared to high-resolution systems (e.g., 3200 Hz), which are commonly used for detecting transient responses such as the H-reflex and M-wave. In a C-EPOCS setup, these responses are useful for determining the target stimulation intensity and minimizing inter-session variability in effective afferent excitation. We evaluated whether lower-resolution EMG signals could still support the generation of H-reflex and M-wave recruitment curves for determining target stimulation intensity. Results showed that while EMG sampled at [~]600 Hz and [~]300 Hz produced greater dispersion in recruitment curve data--particularly at 300 Hz--they still yielded comparable estimates for stimulation intensities that elicit Hmax and Mthreshold, the key parameters for C-EPOCS. Additionally, we demonstrate the feasibility of using an automated response delineation algorithm under these conditions. Despite reduced signal clarity, the algorithm reliably identifies M-wave and H-reflex responses in real time. Overall, this study demonstrates the feasibility of a portable C-EPOCS system capable of providing immediate feedback based on both EMG and EEG signals. It also offers practical recommendations for selecting acquisition hardware to support reliable signal quality, real-time processing, and portability.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 10 Years of EPOC: A scoping review of Emotiv's portable EEG device
Nikolas Williams, Genevieve M. McArthur, Nicholas A. Badcock·bioRxiv·Jul 14, 2020
- EPOC outside the shield: comparing the performance of a consumer-grade EEG device in shielded and unshielded environments.
Jordan Wehrman, Sidsel Sörensen, … Nicholas A. Badcock·Biomedical Physics & Engineering ExpressPeer-reviewed·Jan 22, 2021
- Open-Source, High-Speed and High-Resolution Data Acquisition Platform for Biopotential Recordings and Neural EIT applications
Enrico Ravagli, Alistair Lee McEwan, Kirill Y. Aristovich·Physiological MeasurementPeer-reviewed·Oct 26, 2026
- Design and validation of a novel portable electrode holder for motor-related EEG measurement
Mori Fukuda, Masaaki Hayashi, … Junichi Ushiba·bioRxiv·Mar 5, 2026
- Alpha Neurofeedback Training with a portable Low-Priced and Commercially Available EEG Device Leads to Faster Alpha Enhancement.A Single-blind, Sham-feedback Controlled Study & Methodological Review
Adrian Naas, João Rodrigues, … Andreas Sonderegger·PLoS ONEPeer-reviewed·Sep 4, 2019
- Parameter-Dependent Effects of Spinal Cord Stimulation on Neural Activation and Evoked Compound Action Potentials
Meagan K. Brucker-Hahn, Hans J. Zander, … Scott F. Lempka·bioRxiv·Aug 4, 2026