Air and surface contamination in non-health care settings among 641 environmental specimens of 39 COVID-19 cases
Lei Luo, Dan LiuiD, Hao ZhangiD, Zhihao LiiD, Ruonan Zhen, Xiru Zhang, Huaping XieiD, Wei-Qi SongiD, Jie LiuiD, Qingmei HuangiD, Jingwen LiuiD, Xingfen YangiD, Zongqiu Chen, Chen MaoiD
Abstract
BackgroundLittle is known about the SARS-CoV-2 contamination of environmental surfaces and air in non-health care settings among COVID-19 cases. Methods and findingsWe explored the SARS-CoV-2 contamination of environmental surfaces and air by collecting air and swabbing environmental surfaces among 39 COVID-19 cases in Guangzhou, China. The specimens were tested by RT-PCR testing. The information collected for COVID-19 cases included basic demographic, clinical severity, onset of symptoms, radiological testing, laboratory testing and hospital admission. A total of 641 environmental surfaces and air specimens were collected among 39 COVID-19 cases before disinfection. Among them, 20 specimens (20/641, 3.1%) were tested positive from 9 COVID-19 cases (9/39, 23.1%), with 5 (5/101, 5.0%) positive specimens from 3 asymptomatic cases, 5 (5/220, 2.3%) from 3 mild cases, and 10 (10/374, 2.7%) from 3 moderate cases. All positive specimens were collected within 3 days after diagnosis, and 10 (10/42, 23.8%) were found in toilet (5 on toilet bowl, 4 on sink/faucet/shower, 1 on floor drain), 4 (4/21, 19.0%) in anteroom (2 on water dispenser/cup/bottle, 1 on chair/table, 1 on TV remote), 1 (1/8, 12.5%) in kitchen (1 on dining-table), 1 (1/18, 5.6%) in bedroom (1 on bed/sheet pillow/bedside table), 1 (1/5, 20.0%) in car (1 on steering wheel/seat/handlebar) and 3 (3/20, 21.4%) on door knobs. Air specimens in room (0/10, 0.0%) and car (0/1, 0.0%) were all negative. ConclusionsSARS-CoV-2 was found on environmental surfaces especially in toilet, and could survive for several days. We provided evidence of potential for SARS-CoV-2 transmission through contamination of environmental surfaces.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 42
- FWCI
- 5.21
- Field percentile
- top 3%
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Air and surface measurements of SARS-CoV-2 inside a bus during normal operation
P. Di Carlo, P. Chiacchiaretta, … C. Ucciferri·bioRxiv·Jun 26, 2020
- Disinfection of SARS-CoV-2 contaminated surfaces of personal items with UVC-LED disinfection boxes
M. Bormann, M. Alt, … A. Krawczyk·bioRxiv·Mar 3, 2021
- Decontamination of Common Healthcare Facility Surfaces Contaminated with SARS-CoV-2 using Peracetic Acid Dry Fogging
T. Cutts, S. Kasloff, … J. Krishnan·bioRxiv·Dec 4, 2020
- Aerodynamic Characteristics and RNA Concentration of SARS-CoV-2 Aerosol in Wuhan Hospitals during COVID-19 Outbreak
- Sentinel Cards Provide Practical SARS-CoV-2 Monitoring in School Settings
Victor Cantu, Karenina Sanders, … Rob D. Knight·mSystemsPeer-reviewed·Jun 15, 2022
- Rapid inactivation of SARS-CoV-2 on copper touch surfaces determined using a cell culture infectivity assay
C. W. Keevil, C. A. Bryant, S. A. Wilks·bioRxiv·Jan 2, 2021