Imaging NeuroscienceBiophysicsPeer-reviewed journal article
Frequency-dependence in multidimensional diffusion-relaxation correlation MRI of the brain: overfitting or meaningful parameter?
Maxime YoniD, Omar NarvaeziD, Jan MartiniD, Hong JiangiD, Diana BerniniD, Eva B. Forssell-AronssoniD, Frederik Bernd LauniD, Alejandra SierraiD, Daniel TopgaardiD
Abstract
Time- or frequency-dependent ("restricted") diffusion potentially provides useful information about cellular-scale structures in the brain but is challenging to interpret because of the intravoxel tissue heterogeneity. Frequency-dependence was recently incorporated in a multidimensional diffusion-relaxation correlation MRI framework relying on tensor-valued diffusion encoding at multiple frequencies, as well as variable echo and repetition times, to give model-free characterization of intravoxel heterogeneity by Monte Carlo data inversion into nonparametric distributions of frequency-dependent diffusion tensors and nuclear relaxation rates. While microimaging equipment with high-amplitude magnetic field gradients allows exploration of frequencies from tens to hundreds of Hz, clinical scanners with more moderate gradient capabilities are limited to a narrow frequency range, which may be insufficient to observe effects of restricted diffusion for brain tissues. We here investigate the effects of including or omitting frequency-dependence in the data inversion from isotropic and anisotropic liquids, excised tumor tissue, ex vivo mouse brain, and in vivo human brain. For microimaging measurements covering a wide frequency range, from 35 to 320 Hz at b-values over 4{middle dot}109 sm-2, the inclusion of frequency-dependence drastically reduces the fit residuals and avoids bias in the diffusion metrics for tumor and brain voxels with micrometer-scale structures. Conversely, for the case of in vivo human brain investigated in the narrow frequency range from 5 to 11 Hz at b = 3{middle dot}109 sm-2, analyses with and without inclusion of frequency-dependence yield similar fit residuals and diffusion metrics for all voxels. These results indicate that frequency-dependent inversion may be generally applied to diffusion-relaxation correlation MRI data with and without observable effects of restricted diffusion.
- Citations
- 5
- FWCI
- 1.34
- Field percentile
- top 21%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In vivo disentanglement of diffusion frequency-dependence, tensor shape, and relaxation using multidimensional MRI
Jessica T. E. Johnson, Mustafa Okan Irfanoglu, … Dan Benjamini·Human Brain MappingPeer-reviewed·May 1, 2024
- Ex vivo massively multidimensional diffusion-relaxation correlation MRI: scan-rescan reproducibility and caveats
Pak Or, Maxime Yon, … Dan Benjamini·bioRxiv·Mar 17, 2025
- The variability of multidimensional diffusion-relaxation MRI estimates in the human brain
Eppu Manninen, Shunxing Bao, … Dan Benjamini·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Visualizing orientation-specific relaxation-diffusion features mapped onto orientation distribution functions estimated via nonparametric Monte Carlo MRI signal inversion
João P. de Almeida Martins, Chantal M. W. Tax, … Daniel Topgaard·Human Brain MappingPeer-reviewed·Oct 6, 2020
- Water Diffusion in the Live Human Brain is Gaussian at the Mesoscale
K. N. Magdoom, A. V. Avram, … P. J. Basser·bioRxiv·Apr 10, 2024
- Towards Mesoscopic Human Brain Imaging Using Non-Parametric Diffusion Tensor Distribution (DTD) MRI
Kulam Najmudeen Magdoom, Joelle E. Sarlls, Peter J. Basser·bioRxiv·Apr 15, 2026