Optimization of anastomotic technique and gastric conduit perfusion with hyperspectral imaging in an experimental model for minimally invasive esophagectomy
F. Nickel, A. Studier-Fischer, B. Oezdemir, J. Odenthal, L.-R. Mueller, S. Knoedler, K.-F. Kowalewski, I. Camplisson, M. M. Allers, M. Dietrich, K. Schmidt, G. A. Salg, H. G. Kenngott, A. Billeter, I. Gockel, C. Sagiv, O. Etz-Hadar, J. Gildenblat, L. Ayala, S. Seidlitz, L. Maier-Hein, B. P. Mueller-Stich
Abstract
ObjectiveTo optimize anastomotic technique and gastric conduit perfusion with hyperspectral imaging (HSI) for total minimally invasive esophagectomy (MIE) with linear stapled anastomosis. Summary Background DataEsophagectomy is the mainstay of esophageal cancer treatment but anastomotic insufficiency related morbidity and mortality remain challenging for patient outcome. MethodsA live porcine model (n=50) for MIE was used with gastric conduit formation and linear stapled side-to-side esophagogastrostomy. Four main experimental groups differed in stapling length (3 vs. 6 cm) and anastomotic position on the conduit (cranial vs. caudal). Tissue oxygenation around the anastomotic site was evaluated using HSI and was validated with histopathology. ResultsThe tissue oxygenation ({Delta}StO2) after the anastomosis remained constant only for the short stapler in caudal position (-0.4{+/-} 4.4%, n.s.) while it dropped markedly in the other groups (short-cranial: -15.6{+/-} 11.5%, p=0.0002; long-cranial: -20.4{+/-} 7.6%, p=0.0126; long-caudal: -16.1{+/-} 9.4%, p<0.0001) Tissue samples from deoxygenated stomach as measured by HSI showed correspondent eosinophilic pre-necrotic changes in 35.7{+/-} 9.7% of the surface area. ConclusionsTissue oxygenation at the anastomotic site of the gastric conduit during MIE is influenced by stapling technique. Optimal oxygenation was achieved with a short stapler (3 cm) and sufficient distance of the anastomosis to the cranial end of the gastric conduit. HSI tissue deoxygenation corresponded to histopathologic necrotic tissue changes. These findings allow for optimization of gastric conduit perfusion and anastomotic technique in MIE. Level of EvidenceNot applicable. Translational animal science. Original article.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Functional Imaging for Regenerative Medicine and Tissue-Engineered Constructs: Tracking Vascularization of Tissue-Engineered Small Intestine Scaffolds
Jared A. Weis, Mani Ratnam Kothamasu, … Mitchell R. Ladd·bioRxiv·Sep 25, 2025
- Transforming Esogastric Cancer Surgery Integrating SpiderMass Mass Spectrometry with Clinical and Microbiome Data for Margin Delineation and Prognosis
Léa Ledoux, Yanis Zirem, … Isabelle Fournier·bioRxiv·Oct 13, 2025
- The creation of functioning gastrojejunostomy following magnetic compression
- Hybrid diffuse optical monitoring of hemodynamic changes following acute cerebral ischemia in a porcine model
Detian Wang, Long Wang, … Feng Hua·bioRxiv·Aug 7, 2020
- Photoacoustic Imaging as a Novel Non-Invasive Biomarker to Assess Intestinal Tissue Oxygenation and Motility in Neonatal Rats
V. G. Weis, N. Cruz-Diaz, … J. A. Weis·Journal of Pediatric SurgeryPeer-reviewed·Mar 1, 2024
- Photoacoustic Imaging for Non-Invasive Assessment of Physiological Biomarkers of Intestinal Injury in Experimental Necrotizing Enterocolitis
J. A. Weis, J. L. Rauh, … V. G. Weis·bioRxiv·Oct 20, 2023