Reliability of the TMS-evoked potential in dorsolateral prefrontal cortex
Juha GogulskiiD, Christopher C. ClineiD, Jessica Marie RossiD, Sara ParmigianiiD, Corey J. KelleriD
Abstract
BackgroundWe currently lack a robust and reliable method to probe cortical excitability noninvasively from the human dorsolateral prefrontal cortex (dlPFC), a region heavily implicated in psychiatric disorders. We recently found that the strength of early and local dlPFC single pulse transcranial magnetic stimulation (TMS)-evoked potentials (EL-TEPs) varied widely depending on the anatomical subregion probed, with more medial regions eliciting stronger responses than anterolateral sites. Despite these differences in amplitude of response, the reliability at each target is not known. ObjectiveTo evaluate the reliability of EL-TEPs across the dlPFC. MethodsIn 15 healthy subjects, we quantified within-session reliability of dlPFC EL-TEPs after single pulse TMS to six dlPFC subregions. We evaluated the concordance correlation coefficient (CCC) across targets and analytical parameters including time window, quantification method, region of interest, sensor-vs. source-space, and number of trials. ResultsAt least one target in the anterior and posterior dlPFC produced reliable EL-TEPs (CCC>0.7). The medial target was most reliable (CCC = 0.78) and the most anterior target was least reliable (CCC = 0.24). ROI size and type (sensor vs. source space) did not affect reliability. Longer (20-60 ms, CCC = 0.62) and later (30-60 ms, CCC = 0.61) time windows resulted in higher reliability compared to earlier and shorter (20-40 ms, CCC 0.43; 20-50 ms, CCC = 0.55) time windows. Peak-to-peak quantification resulted in higher reliability than the mean of the absolute amplitude. Reliable EL-TEPs (CCC up to 0.86) were observed using only 25 TMS trials for a medial dlPFC target. ConclusionsMedial TMS location, wider time window (20-60ms), and peak-to-peak quantification improved reliability. Highly reliable EL-TEPs can be extracted from dlPFC after only a small number of trials. HighlightsO_LIMedial dlPFC target improved EL-TEP reliability compared to anterior targets. C_LIO_LIAfter optimizing analytical parameters, at least one anterior and one posterior target was reliable (CCC>0.7). C_LIO_LILonger (20-60 ms) and later (30-60 ms) time windows were more reliable than earlier and shorter (20-40 ms or 20-50 ms) latencies. C_LIO_LIPeak-to-peak quantification resulted in higher reliability compared to the mean of the absolute amplitude. C_LIO_LIAs low as 25 trials can yield reliable EL-TEPs from the dlPFC. C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 20
- FWCI
- 3.12
- Field percentile
- top 8%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mapping cortical excitability in the human dorsolateral prefrontal cortex
Juha Gogulski, Christopher C. Cline, … Corey J. Keller·bioRxiv·Jan 20, 2023
- Test-retest reliability of TMS-evoked potentials over fMRI-based definitions of non-motor cortical targets
Ceyda Sayalı, Juha Gogulski, … Frederick Streeter Barrett·bioRxiv·Dec 20, 2024
- Real-time optimization to enhance noninvasive cortical excitability assessment in the human dorsolateral prefrontal cortex
Sara Parmigiani, Christopher C. Cline, … Corey J. Keller·bioRxiv·May 29, 2024
- TMS-evoked EEG potentials from prefrontal and parietal cortex: reliability, site specificity, and effects of NMDA receptor blockade
Nigel C. Rogasch, Carl Moritz Zipser, … Ulf Ziemann·bioRxiv·Feb 2, 2019
- Reliability of transcranial magnetic stimulation evoked potentials to detect the effects of theta-burst stimulation of the prefrontal cortex
Adriano H. Moffa, Stevan Nikolin, … Tjeerd W. Boonstra·Neuroimage ReportsPeer-reviewed·Jun 21, 2022
- Evaluation of scalp-based targeting methods of DLPFC for TMS therapy: EEG cap F3, Beam F3, CPC F3, and adjusted Beam F3
Yihan Jiang, Yuanyuan Chen, … Chaozhe Zhu·bioRxiv·Sep 28, 2024