A Geometric View of Signal Sensitivity Metrics in multi-echo fMRI
Thomas T. LiuiD, Bochao LiiD, Brice FernandeziD, Suchandrima Banerjee
Abstract
In multi-echo fMRI (ME-fMRI), two metrics have been widely used to measure the performance of various acquisition and analysis approaches. These are temporal SNR (tSNR) and differential contrast-to-noise ratio (dCNR). A key step in ME-fMRI is the weighted combination of the data from multiple echoes, and prior work has examined the dependence of tSNR and dCNR on the choice of weights. However, most studies have focused on only one of these two metrics, and the relationship between the two metrics has not been examined. In this work, we present a geometric view that offers greater insight into the relation between the two metrics and their weight dependence. We identify three major regimes: (1) a tSNR robust regime in which tSNR is robust to the weight selection with most weight variants achieving close to optimal performance, whereas dCNR shows a pronounced dependence on the weights with most variants achieving suboptimal performance; (2) a dCNR robust regime in which dCNR is robust to the weight selection with most weight variants achieving close to optimal performance, while tSNR exhibits a strong dependence on the weights with most variants achieving significantly lower than optimal performance; and (3) a within-type robust regime in which both tSNR and dCNR achieve nearly optimal performance when the form of the weights are variants of their respective optimal weights and exhibit a moderate decrease in performance for other weight variants. Insight into the behavior observed in the different regimes is gained by considering spherical representations of the weight dependence of the components used to form each metric. For multi-echo acquisitions, dCNR is shown to be more directly related than tSNR to measures of CNR and signal-to-noise ratio (SNR) for both task-based and resting-state fMRI scans, respectively.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.14
- Field percentile
- 39th percentile
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Weight Sensitivity of Temporal SNR Metrics in multi-echo fMRI
Thomas T. Liu, Bochao Li, … Suchandrima Banerjee·bioRxiv·Apr 20, 2020
- Spatial and Temporal Consistency of Brain Networks for different Multi-Echo fMRI Combination Methods
Jesper Pilmeyer, George M. Hadjigeorgiou, … Svitlana Zinger·bioRxiv·Aug 18, 2021
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions
Cornelius Eichner, Michael Paquette, … Alfred Anwander·NeuroImagePeer-reviewed·Jul 15, 2020
- The effects of multi-echo fMRI combination and rapid T2*-mapping on offline and real-time BOLD sensitivity
Stephan Heunis, Marcel M. Breeuwer, … Albert Pierre Aldenkamp·NeuroImagePeer-reviewed·Jun 8, 2021
- Comparing the effect of multi gradient echo and multi band fMRI during a semantic task
Ajay D. Halai, Richard N. Henson, … Marta Correia·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- A new fMRI quality metric using multi-echo information: Theory, validation and implications
Javier González-Castillo, César Caballero‐Gaudes, … Peter A. Bandettini·bioRxiv·Mar 23, 2026