NeuroImageNeurosciencePeer-reviewed journal article
The effects of multi-echo fMRI combination and rapid T2*-mapping on offline and real-time BOLD sensitivity
Stephan HeunisiD, Marcel M. BreeuweriD, César Caballero‐GaudesiD, Lydia HellrungiD, Willem HuijbersiD, Jacobus F.A. JanseniD, Rolf M. J. N. Lamerichs, Svitlana ZingeriD, Albert Pierre AldenkampiD
- Citations
- 31
- FWCI
- 1.98
- Field percentile
- top 14%
Abstract
A variety of strategies are used to combine multi-echo functional magnetic resonance imaging (fMRI) data, yet recent literature lacks a systematic comparison of the available options. Here we compare six different approaches derived from multi-echo data and evaluate their influences on BOLD sensitivity for offline and in particular real-time use cases: a single-echo time series (based on Echo 2), the real-time T2*-mapped time series (T2*FIT) and four combined time series (T2*-weighted, tSNR-weighted, TE-weighted, and a new combination scheme termed T2*FIT-weighted). We compare the influences of these six multi-echo derived time series on BOLD sensitivity using a healthy participant dataset (N=28) with four task-based fMRI runs and two resting state runs. We show that the T2*FIT-weighted combination yields the largest increase in temporal signal-to-noise ratio across task and resting state runs. We demonstrate additionally for all tasks that the T2*FIT time series consistently yields the largest offline effect size measures and real-time region-of-interest based functional contrasts. These improvements show the possible utility of multi-echo fMRI for studies employing real-time paradigms, while caution is still advised due to decreased tSNR of the T2*FIT time series. We recommend the use and continued exploration of T2*FIT for offline task-based and real-time fMRI analysis. Supporting information includes: a data repository (https://dataverse.nl/dataverse/rt-me-fmri), an interactive web-based application to explore the data (https://rt-me-fmri.herokuapp.com/), and further materials and code for reproducibility (https://github.com/jsheunis/rt-me-fMRI).
- assay: imaging
- research focus: benchmarking
- research focus: differential expression
- research focus: dimensionality reduction
- approach: statistical model
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Spatial and Temporal Consistency of Brain Networks for different Multi-Echo fMRI Combination Methods
Jesper Pilmeyer, George M. Hadjigeorgiou, … Svitlana Zinger·bioRxiv·Aug 18, 2021
- Comparing the effect of multi gradient echo and multi band fMRI during a semantic task
Ajay D. Halai, Richard N. Henson, … Marta Correia·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Optimising 7T-fMRI for imaging regions of magnetic susceptibility
Saskia L Frisby, Marta Correia, … Ajay D. Halai·Human Brain MappingPeer-reviewed·Aug 1, 2026
- Leveraging Multi-Echo EPI to Enhance BOLD Sensitivity in Task-based Olfactory fMRI
Ludwig Sichen Zhao, Clara U. Raithel, … Jay A. Gottfried·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Weight Sensitivity of Temporal SNR Metrics in multi-echo fMRI
Thomas T. Liu, Bochao Li, … Suchandrima Banerjee·bioRxiv·Apr 20, 2020
- Mapping Whole-Brain Auditory Activation with 3T Multi-Echo fMRI at the Group and Individual-Subject Level
Michelle C. Medina, Neha A. Reddy, … Molly G. Bright·Hearing ResearchPeer-reviewed·Mar 21, 2026