Understanding the mismatch between in-vivo and in-silico rhinomanometry
Abstract
Numerical simulations and clinical measurements of nasal resistance are in quantitative disagreement. Bias introduced by the design of medical devices has not been considered until now as a possible explanation. The aim of present paper is to study the effect of the location of the probe on the rhinomanometer that is meant to measure the ambient pressure. Rhinomanometry is carried out on a 3D silicone model of a patient-specific anatomy; a clinical device and dedicated sensors are employed side-by-side for mutual validation. The same anatomy is also employed for numerical simulations, with approaches spanning a wide range of fidelity levels. We find that the intrinsic uncertainty of the numerical simulations is of minor importance. To the contrary, the position of the pressure tap intended to acquire the external pressure in the clinical device is crucial, and can cause a mismatch comparable to that generally observed between in-silico and in-vivo rhinomanometry data. A source of systematic bias may therefore exist in rhinomanometers, designed under the assumption that measurements of the nasal resistance are unaffected by the flow development within the instruments.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.94
- Field percentile
- top 23%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An Experimental Validation of the Computer Fluid Dynamics of Normal Human Nasal Airflow Using a Precise 3-D Printing Model
- On the comparison between pre- and post-surgery nasal anatomies via computational fluid dynamics
E. Segalerba, G. Dini Ciacci, … J. O. Pralits·Biomechanics and Modeling in MechanobiologyPeer-reviewed·Oct 30, 2023
- In vitro-in silico correlation of three-dimensional turbulent flows in an idealized mouth-throat model
E. Nof, S. Bhardwaj, … J. Sznitman·bioRxiv·Sep 5, 2022
- Assessing nasal obstruction with the nasal acoustic device: a pilot study on distinguishing between subjects with and without chronic rhinosinusitis
- Noninvasive method for monitoring breathing patterns in monkeys
Jun Kunimatsu, Yusuke Akiyama, … Masayuki Matsumoto·bioRxiv·Aug 31, 2022
- Quantifying and Visualizing the Invisible Hazard of Infant Rebreathing
David Greenblatt, Nadav Itzhak·bioRxiv·Nov 9, 2026