Using muscle-tendon load limits to assess unphysiological musculoskeletal model deformation and Hill-type muscle parameter choice
Lennart V. NölleiD, Isabell WochneriD, Maria HammeriD, Syn SchmittiD
Abstract
Musculoskeletal simulations are a useful tool for improving our understanding of the human body. However, the physiological validity of predicted kinematics and forces is highly dependent upon the correct calibration of muscle parameters and the structural integrity of a models internal skeletal structure. In this study, we show how ill-tuned muscle parameters and unphysiological deformations of a models skeletal structure can be detected by using muscle elements as sensors with which modelling and parameterization inconsistencies can be identified through muscle and tendon strain injury assessment. To illustrate our approach, two modelling issues were recreated. First, a model repositioning simulation using the THUMS AM50 occupant model version 5.03 was performed to show how internal model deformations can occur during a change of model posture. Second, the muscle material parameters of the OpenSim gait2354 model were varied to illustrate how unphysiological muscle forces can arise if material parameters are inadequately calibrated. The simulations were assessed for muscle and tendon strain injuries using previously published injury criteria and a newly developed method to determine tendon strain injury threshold values. Muscle strain injuries in the left and right musculus pronator teres were detected during the model repositioning. This straining was caused by an unphysiologically large gap (12.92 mm) that had formed in the elbow joint. Similarly, muscle and tendon strain injuries were detected in the modified right-hand musculus gastrocnemius medialis of the gait2354 model where an unphysiological reduction of the tendon slack length introduced large pre-strain of the muscle-tendon-unit. The results of this work show that the proposed method can quantify the internal distortion behaviour of musculoskeletal human body models and the validity of Hill-type muscle parameter choice via strain injury assessment. Furthermore, we highlight possible actions to avoid the presented issues and inconsistencies in literature data concerning the material characteristics of human tendons.
- Citations
- 2
- FWCI
- 0.19
- Field percentile
- 31th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Musculotendon Parameters in Lower Limb Models: Simplifications, Uncertainties, and Muscle Force Estimation Sensitivity
Z. Chen, D. W. Franklin·bioRxiv·Nov 4, 2022
- Summary of muscle parameters for Hill-based muscle modeling in the human lower limb
Ross H. Miller·bioRxiv·Dec 7, 2016
- Variability and Impact of Musculoskeletal Modeling Parameters for the Human Elbow
R. L. Hardesty, B. Jeong, D. M. Gemoets·bioRxiv·Oct 29, 2022
- Hill-type models of skeletal muscle and neuromuscular actuators: a systematic review
Arnault Hubert Caillet, Andrew Phillips, … Luca Modenese·IEEE Reviews in Biomedical EngineeringPeer-reviewed·Sep 12, 2025
- Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand
Matthew T. Boots, Russell L. Hardesty, … Sergiy Yakovenko·bioRxiv·May 29, 2020
- Accuracy of experimentally estimated muscle properties: Evaluation and improvement using a newly developed toolbox
Edwin D. H. M. Reuvers, Dinant A. Kistemaker·bioRxiv·Sep 29, 2025