Journal of Proteome ResearchBioinformaticsPeer-reviewed journal article
Rapidly Assessing the Quality of Targeted Proteomics Experiments Through Monitoring Stable-isotope Labeled Standards
Bryson C. GibbonsiD, Thomas FillmoreiD, Yuqian GaoiD, Ronald Jay MooreiD, Tao LiuiD, Ernesto Satoshi NakayasuiD, Thomas MetziD, Samuel PayneiD
Abstract
Targeted proteomics experiments based on selected reaction monitoring (SRM) have gained wide adoption in clinical biomarker, cellular modeling and numerous other biological experiments due to their highly accurate and reproducible quantification. The quantitative accuracy in targeted proteomics experiments is reliant on the stable-isotope, heavy-labeled peptide standards which are spiked into a sample and used as a reference when calculating the abundance of endogenous peptides. Therefore, the quality of measurement for these standards is a critical factor in determining whether data acquisition was successful. With improved MS instrumentation that enables the monitoring of hundreds of peptides in hundreds to thousands of samples, quality assessment is increasingly important and cannot be performed manually. We present Q4SRM, a software tool that rapidly checks the signal from all heavy labeled peptides and flags those that fail quality control metrics. Using four metrics, the tool detects problems both with individual SRM transitions and the collective group of transitions that monitor a single peptide. The programs speed enables its use at the point of data acquisition and can be ideally run immediately upon the completion of an LC-SRM-MS analysis.
- assay: proteomics
- research focus: benchmarking
- research focus: software / tool
- approach: statistical model
- Citations
- 11
- FWCI
- 0.43
- Field percentile
- top 50%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Hybrid Quadrupole Mass Filter Radial Ejection Linear Ion Trap and Intelligent Data Acquisition Enable Highly Multiplex Targeted Proteomics
Philip M. Remes, Cristina C. Jacob, … Michael J. MacCoss·Journal of Proteome ResearchPeer-reviewed·Oct 30, 2024
- Automated SWATH Data Analysis Using Targeted Extraction of Ion Chromatograms
Hannes L Röst, Ruedi Aebersold, Olga T Schubert·bioRxiv·Mar 19, 2016
- Comparison of unit resolution versus high-resolution accurate mass for parallel reaction monitoring
L. R. Heil, P. M. Remes, M. J. MacCoss·bioRxiv·May 4, 2021
- Light contamination in stable isotope-labelled internal peptide standards is frequent and a potential source of false discovery and quantitation error in proteomics
M. Salek, J. D. Foerster, … A. B. Riemer·bioRxiv·Nov 8, 2021
- Rapid QC-MS - Interactive Dashboard for Synchronous Mass Spectrometry Data Acquisition Quality Control
W. Sandhu, I. J. Gray, … B. C. DeFelice·bioRxiv·Jan 30, 2024
- Quartet protein reference materials and datasets for multi-platform assessment of label-free proteomics
Sha Tian, Dongdong Zhan, … Chen Ding·Genome biologyPeer-reviewed·Sep 6, 2023