bioRxivBioengineering
Mechanically Matched Silicone Brain Implants Reduce Brain Foreign Body Response
E. Zhang, A. Alameri, J.-P. Clement, A. Ng, T. E. Kennedy, D. Juncker
Abstract
Brain implants are increasingly used to treat neurological disorders and diseases. However, the brain foreign body response (FBR) elicited by implants affects neuro-electrical transduction and long-term reliability limiting their clinical adoption. The mismatch in Youngs modulus between silicon implants ([~]180 GPa) and brain tissue ([~]1-30 kPa) exacerbates the FBR resulting in the development of flexible implants from polymers such as polyimide ([~]1.5-2.5 GPa). However, a stiffness mismatch of at least two orders of magnitude remains. Here, we introduce (i) the first mechanically matched brain implant (MMBI) made from silicone ([~]20 kPa), (ii) new microfabrication methods, and (iii) a novel dissolvable sugar shuttle to reliably implant MMBIs. MMBIs were fabricated via vacuum-assisted molding using sacrificial sugar molds and were then encased in sugar shuttles that dissolved within 2 min after insertion into rat brains. Sections of rat neocortex implanted with MMBIs, PDMS implants, and silicon implants were analyzed by immunohistochemistry 3 and 9-weeks post-implantation. MMBIs resulted in significantly higher neuronal density and lower FBR within 50 {micro}m of the tissue-implant interface compared to PDMS and silicon implants suggesting that materials mechanically matched to brain further minimize the FBR and could contribute to better implant functionality and long-term reliability.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mechanically Compliant, Precision-Porous Brain Implants Reduce the Foreign Body Reaction and Guide Regeneration
Ian D. Dryg, Le Zhen, … Buddy D. Ratner·Advanced Healthcare MaterialsPeer-reviewed·Aug 3, 2026
- A microfabricated, 3D-sharpened silicon shuttle for insertion of flexible electrode arrays through dura mater into brain
Hannah R. Joo, Jiang Lan Fan, … Loren M. Frank·Journal of Neural EngineeringPeer-reviewed·Jun 19, 2019
- Friend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants
Corinne Orlemann, Laura M. De Santis, … Pieter R. Roelfsema·Advanced SciencePeer-reviewed·Apr 15, 2026
- Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
J. R. Abbott, E. N. Jeakle, … S. F. Cogan·bioRxiv·Nov 2, 2023
- Mechanical flexibility reduces the foreign body response to long- term implanted microelectrodes in rabbit cortex
Harbaljit S Sohal, Gavin J Clowry, … Stuart N Baker·bioRxiv·Jun 14, 2016
- Stiffness-tunable neurotentacles for minimally invasive implantation and long-term neural activity recordings
Yang Wang, Xing Xu, … Weihua Pei·Advanced SciencePeer-reviewed·Jul 21, 2025