Advanced ScienceBioengineeringPeer-reviewed journal article
Friend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants
Corinne OrlemanniD, Laura M. De Santis, Paul Neering, Christian BoehleriD, Kirti SharmaiD, Arno A. A. AartsiD, Tobias HolzhammeriD, Rik J. J. van DaaliD, Patrick RutheriD, Maria AsplundiD, Roxana N. KooijmansiD, Pieter R. RoelfsemaiD
Abstract
One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.
- Citations
- 1
- FWCI
- 2.49
- Field percentile
- top 16%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Intracortical probe arrays with silicon backbone and microelectrodes on thin polyimide wings enable long-term stable recordings in vivo
Antje Kilias, Yu‐Tao Lee, … Patrick Ruther·Journal of Neural EngineeringPeer-reviewed·Nov 15, 2021
- Stiffness-tunable neurotentacles for minimally invasive implantation and long-term neural activity recordings
Yang Wang, Xing Xu, … Weihua Pei·Advanced SciencePeer-reviewed·Jul 21, 2025
- Structural and functional changes of pyramidal neurons at the site of an implanted microelectrode array in rat primary motor cortex
B. A. Gregory, C. H. Thompson, … E. K. Purcell·bioRxiv·Sep 15, 2022
- Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
J. R. Abbott, E. N. Jeakle, … S. F. Cogan·bioRxiv·Nov 2, 2023
- Stability of Thin-Film Metallization in Flexible Stimulation Electrodes: Analysis and Improvement of in vivo Performance
P. Cvancara, T. Boretius, … T. Stieglitz·bioRxiv·May 22, 2019
- Double-layer flexible neuronal probe with closely spaced electrodes for high-density in vivo brain recordings
S. Pimenta, J. A. Rodrigues, … L. Jacinto·bioRxiv·Oct 15, 2020