Field-Correcting GRAPPA (FCG): a technique to correctspatiotemporal-varying phase errors in Echo Planar Imaging
Nan WangiD, Daniel AbrahamiD, Zachary ShahiD, Yimeng LiniD, Xiaozhi CaoiD, Hua WuiD, Jon̈athan R. PolimeniiD, Laurentius HuberiD, Quanle Liu, Lipeng NingiD, Yogesh Rathi AiD, Carl‐Fredrik WestiniD, Hendrik MatterniD, Oliver SpeckiD, Baolian Yang, Nastaren AbadiD, Congyu LiaoiD, Adam B. KerriD, Kawin SetsompopiD
Abstract
PurposeTo develop a Field-Correcting GRAPPA (FCG) technique to correct the spatiotemporal-varying phase errors in EPI caused by eddy currents. MethodsThe fast-changing gradient in EPI causes strong eddy current effects and associated spatiotemporal-varying phase errors, producing significant image artifacts. The use of higher gradient amplitude, slew rate, and ramp sampling factor for faster imaging exacerbates this problem. In this work, FCG was developed to address this challenge by using a multi-layer perceptron (MLP) to provide a compact representation of a family of GRAPPA-like kernels that correct the spatiotemporal-varying phase errors in the data. A dedicated calibration pipeline was designed to acquire high-quality source and target data for MLP training in both slice-by-slice and simultaneous multi-slice (SMS) acquisitions. To validate FCGs assumptions and performance, a field camera was used to provide ground-truth measurement of phase patterns. The performance of FCG was further validated on phantom and in vivo experiments using demanding EPI trajectories across multiple 3T and 7T systems. ResultsField camera measurements revealed strong spatiotemporal phase variations along the kx direction that repeat along ky during EPI readouts. The experiments on high-performance systems across 3T and 7T demonstrate that FCG can provide superior correction for the artifacts induced by spatiotemporal-varying phase errors compared with existing approaches. ConclusionFCG is an effective and robust method for correcting spatiotemporal phase errors in EPI, enabling improved image quality on high-performance systems.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 2
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Impact of Autocalibration Method on Accelerated Echo-Planar Imaging of the Cervical Spinal Cord at 7T
A. C. Seifert, J. Xu·bioRxiv·Mar 8, 2022
- The Simultaneous Measurement of Reversed Phase-Encoding EPI in a Single fMRI Session: Evaluation of Geometric Distortion Correction in Submillimetre fMRI at 7T
Seong Dae Yun, Erhan Genç, … N. Jon Shah·bioRxiv·Sep 26, 2024
- Exploiting Four-way Phase-encoding Benefits for Robust Detection and Correction of EPI artifacts: Application to Residual Ghosts in Diffusion MRI.
Anh Thai, Lin‐Ching Chang, … Mustafa Okan Irfanoglu·Magnetic Resonance ImagingPeer-reviewed·Jul 7, 2025
- Anatomy-guided Inverse-phase-encoding Registration Method for Correcting Susceptibility Artifacts in Sub-millimeter fMRI
Soan T. M. Duong, Son Lam Phung, … Mark M. Schira·bioRxiv·Sep 23, 2019
- Improving robustness of 3D multi-shot EPI by structured low-rank reconstruction of segmented CAIPI sampling for fMRI at 7T
Xi Chen, Wenchuan Wu, Mark Chiew·NeuroImagePeer-reviewed·Dec 23, 2022
- Assessing methods for geometric distortion compensation in 7T gradient echo fMRI data
Michael‐Paul Schallmo, Kimberly B. Weldon, … Cheryl A. Olman·Human Brain MappingPeer-reviewed·Jun 22, 2021