Impact of Autocalibration Method on Accelerated Echo-Planar Imaging of the Cervical Spinal Cord at 7T
Abstract
PurposeThe spinal cord contains sensorimotor neural circuits of scientific and clinical interest. However, spinal cord fMRI is significantly more technically demanding than brain fMRI due primarily to its proximity to the lungs. Accelerated EPI at 7T is particularly vulnerable to k-space phase inconsistencies induced by motion or B0 fluctuation, during either autocalibration signal (ACS) or timeseries acquisition. For 7T brain fMRI, sensitivity to motion and B0 fluctuation can be reduced using a re-ordered segmented EPI ACS based on the fast low-angle excitation echo-planar technique (FLEET). However, respiration-induced B0 fluctuations (exceeding 100Hz at C7) are greater, and fewer k-space lines per slice are required, for cervical spinal cord fMRI at 7T, necessitating a separate evaluation of ACS methods. MethodsWe compared 24-line single-shot EPI, and 48-line two-shot segmented EPI, two-shot FLEET, and GRE-based ACS acquisition methods, performed under various physiological conditions, in terms of temporal SNR (tSNR) and prevalence of artifacts in GRAPPA-accelerated EPI of the cervical spinal cord at 7T. ResultsSegmented EPI and FLEET ACS produce images with nearly identical patterns of severe image artifacts. GRE and single-shot EPI ACS consistently produce images free from significant artifacts, and tSNR is significantly greater for GRE ACS, particularly in lower slices where through-slice dephasing is most severe. ConclusionGRE and single-shot EPI ACS acquisition methods, which are robust to respiration-induced phase errors between k-space segments, produce images with fewer and less severe artifacts than either FLEET or conventionally segmented EPI for accelerated EPI of the cervical spinal cord at 7T.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Thermal Stimulus Task fMRI in the Cervical Spinal Cord at 7 Tesla
A. C. Seifert, J. Xu, … S. J. Vannesjo·bioRxiv·Jan 31, 2023
- Field-Correcting GRAPPA (FCG): a technique to correctspatiotemporal-varying phase errors in Echo Planar Imaging
Nan Wang, Daniel Abraham, … Kawin Setsompop·bioRxiv·Jul 10, 2026
- EPISeg: Automated segmentation of the spinal cord on echo planar images using open-access multi-center data
Rohan Banerjee, Merve Kaptan, … Julien Cohen‐Adad·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Trace-based correction of breathing-induced field fluctuations in T2*-weighted imaging of the spinal cord
S Johanna Vannesjo, Stuart Clare, … Karla L. Miller·bioRxiv·Sep 5, 2018
- Improving robustness of 3D multi-shot EPI by structured low-rank reconstruction of segmented CAIPI sampling for fMRI at 7T
Xi Chen, Wenchuan Wu, Mark Chiew·NeuroImagePeer-reviewed·Dec 23, 2022
- Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars Kasper, Maria Engel, … Klaas P. Pruessmann·NeuroImagePeer-reviewed·Nov 17, 2021