bioRxivNeurosciencePreprint
Increasing pulse energy of 5Hz rTMS improves its efficacy in inducing excitatory aftereffects.
Islam HalawaiD, K Reichert, Swathi AniliD, Martin SommeriD, Walter PaulusiD
Abstract
IntroductionHigh frequency repetitive transcranial magnetic stimulation induces excitation when applied to the motor cortex as reflected by the increase MEP amplitudes after the stimulation. The effects differ according to pulse width, probably due to higher content of energy in the wider pulses and their ability to cause wider activation in comparison to shorter pulse shapes. Here we focus on the aftereffects generated with high frequency controllable pulse TMS (cTMS) with different pulse widths. ObjectivesTo investigate the influence of pulse energy by using different stimulation intensities and pulse widths on the excitatory plastic aftereffects of high frequency (HF) rTMS. MethodsUsing a controllable pulse stimulator TMS (cTMS), we stimulated the hand motor cortex with 5 Hz rTMS applying 1200 bidirectional pulses with the main component widths of 80, 100 and 120 microseconds. 14 healthy subjects were initially investigated for six randomized sessions first with 80% RMT for anterior-posterior (AP) and posterior-anterior (PA). Then three more sessions using same pulse widths were added for 90% RMT anterior-posterior (AP). Results80% HF rTMS did not produce any significant excitation in either AP or PA direction. 90% RMT AP stimulation with 100 and 120 microsecond-wide pulses were more excitatory, when compared to the 80 microsecond-wide pulses. We also found a correlation between the individual pulse energy and the plastic outcome of each session. ConclusionsHF rTMS with wider pulses is more effective in producing excitatory aftereffects, an effect that correlated with the higher energy content of wider pulses and higher intensity. SignificanceThe findings here suggest that wider pulses are capable of inducing more excitation, a fact that could contribute to better results in future clinical studies performed with wider pulses.
- Citations
- 4
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 1 Hz rTMS Is Not Inherently Inhibitory: Current Direction Determines Aftereffects and Reliability
Carolina Kanig, Mirja Osnabruegge, … Stefan Schoisswohl·bioRxiv·Jul 2, 2026
- Inhibiting corticospinal excitability by entraining ongoing mu-alpha rhythm in motor cortex
E. A. Zmeykina, Zsolt Turi, … Walter Paulus·bioRxiv·Nov 11, 2020
- Short-lived alpha power suppression induced by low-intensity arrhythmic rTMS
Elina Zmeykina, Matthias Mittner, … Zsolt Turi·NeurosciencePeer-reviewed·May 2, 2021
- Bandpass corticospinal transmission during repetitive TMS revealed by motor unit recordings
Hélio V. Cabral, Milena Aguiar dos Santos, … Francesco Negro·bioRxiv·May 22, 2026
- Repetitive suprathreshold paired-pulse transcranial magnetic stimulation alters corticospinal excitability
Suraj Suresh, Wei‐Yeh Liao, … Nigel C. Rogasch·bioRxiv·Oct 21, 2026
- High-density theta burst stimulation (hdTBS) at 100 Hz triples the aftereffects of the conventional intermittent TBS
Aidan Carney, Taylor Scott, … Hanbing Lu·Transcranial magnetic stimulation .Peer-reviewed·Jul 14, 2026