Micro-CT analyses of the lung in mice: Parameters influencing the radiation dose and acquisition quality
S. Körner, C. Körbel, Y. Dzierma, K. Speicher, M. W. Laschke, C. Rübe, M. D. Menger, M. Linxweiler
Abstract
Microcomputed tomography (micro-CT) is a frequently used imaging tool for a wide spectrum of in-vivo mouse models in basic and translational research. To allow an accurate interpretation of micro-CT images, high spatial resolution is necessary. However, this may also lead to a high radiation exposure of the animals. Therefore, animal welfare requires exact information about the expected radiation doses for experimental planning. To gain this, a mouse cadaver was herein used for micro-CT analyses under different conditions. For each radiation dose measurement, the cadaver was labeled with thermoluminescent dosimeter chips around the thoracic skin surface. Micro-CT scans of the thorax were performed with spatial resolutions of 35 {micro}m, 18 {micro}m and 9 {micro}m in combination with Al0.5, Al1.0, CuAl and Cu filters. As a surrogate of image quality, the number of identifiable lung vessels was counted on a transversal micro-CT slice. Measured radiation doses varied from 0.09 Gy up to 5.18 Gy dependent on resolution and filter settings. A significant dose reduction of > 75% was achieved by a Cu filter when compared to an Al0.5 filter. However, this resulted in a markedly reduced image quality and interpretability of microstructures due to higher radiation shielding and lower spatial resolution. Thus, the right combination of distinct filters and several scan protocol settings adjusted to the individual requirements can significantly reduce the radiation dose of micro-CT leading to a higher animal welfare standard.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Radiosafe micro-computed tomography for longitudinal evaluation of murine disease models
N. Berghen, K. Dekoster, … G. Vande Velde·bioRxiv·Nov 20, 2019
- The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging
S. J. Blocker, M. D. Holbrook, … C. Badea·bioRxiv·Oct 29, 2019
- Murine Radiation-Induced Stomach Pathology from Whole Thoracic Irradiation
D. R. McIlrath, C. J. Perez-Torres·bioRxiv·Mar 6, 2020
- Achieving Micrometer-Scale 4D X-ray tomography of Living Leaf Tissue in the Laboratory
F. Siracusa, E.V. Kristensen, … Rajmund Mokso·Plant MethodsPeer-reviewed·Aug 4, 2026
- High Throughput PET/CT Imaging Using a Multiple Mouse Imaging System
H. E. Greenwood, Z. Nyitrai, … T. H. Witney·bioRxiv·Apr 11, 2019
- Evaluation of longitudinal time-lapsed in vivo micro-CT for monitoring fracture healing in mouse femur defect models
E. Wehrle, D. C. Tourolle ne Betts, … R. Mueller·bioRxiv·Oct 17, 2019