QSMRim-Net: Imbalance-Aware Learning for Identification of Chronic Active Multiple Sclerosis Lesions on Quantitative Susceptibility Maps

Hang ZhangiD, Thanh Duc NguyeniD, Jinwei ZhangiD, Melanie Marcille, Pascal SpincemailleiD, Yi WangiD, Susan A. GauthieriD, Elizabeth M. SweeneyiD

Abstract

Background and PurposeChronic active multiple sclerosis (MS) lesions are characterized by a paramagnetic rim at the edge of the lesion and are associated with increased disability in patients. Quantitative susceptibility mapping (QSM) is an MRI technique that is sensitive to chronic active lesions, termed rim+ lesions on the QSM. We present QSMRim-Net, a data imbalance-aware deep neural network that fuses lesion-level radiomic and convolutional image features for automated identification of rim+ lesions on QSM. MethodsQSM and T2-weighted-Fluid-Attenuated Inversion Recovery (T2-FLAIR) MRI of the brain were collected at 3T for 172 MS patients. Rim+ lesions were manually annotated by two human experts, followed by consensus from a third expert, for a total of 177 rim+ and 3986 rim negative (rim-) lesions. Our automated rim+ detection algorithm, QSMRim-Net, consists of a two-branch feature extraction network and a synthetic minority oversampling network to classify rim+ lesions. The first network branch is for image feature extraction from the QSM and T2-FLAIR, and the second network branch is a fully connected network for QSM lesion-level radiomic feature extraction. The oversampling network is designed to increase classification performance with imbalanced data. ResultsOn a lesion-level, in a five-fold cross validation framework, the proposed QSMRim-Net detected rim+ lesions with a partial area under the receiver operating characteristic curve (pROC AUC) of 0.760, where clinically relevant false positive rates of less than 0.1 were considered. The method attained an area under the precision recall curve (PR AUC) of 0.704. QSMRim-Net out-performed other state-of-the-art methods applied to the QSM on both pROC AUC and PR AUC. On a subject-level, comparing the predicted rim+ lesion count and the human expert annotated count, QSMRim-Net achieved the lowest mean square error of 0.98 and the highest correlation of 0.89 (95% CI: 0.86, 0.92). ConclusionThis study develops a novel automated deep neural network for rim+ MS lesion identification using T2-FLAIR and QSM images.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISLou '21Bollmann '19Bollmann '19Rachmadi '19Stewart '23Ma '25
72% semantic matchNeuroscience