SHARQnet - Sophisticated Harmonic Artifact Reduction in Quantitative Susceptibility Mapping using a Deep Convolutional Neural Network
Steffen BollmanniD, Matilde Holm KristenseniD, Morten Skaarup LarseniD, Mathias Vassard OlseniD, Mads Jozwiak PederseniD, Lasse Riis ØstergaardiD, Kieran O’BrieniD, Christian LangkammeriD, Amir FazlollahiiD, Markus BarthiD
Abstract
Quantitative susceptibility mapping (QSM) reveals pathological changes in widespread diseases such as Parkinsons disease, Multiple Sclerosis, or hepatic iron overload. QSM requires multiple processing steps after the acquisition of magnetic resonance imaging (MRI) phase measurements such as unwrapping, background field removal and the solution of an ill-posed field-to-source-inversion. Current techniques utilize iterative optimization procedures to solve the inversion and background field correction, which are computationally expensive and lead to suboptimal or over-regularized solutions requiring a careful choice of parameters that make a clinical application of QSM challenging. We have previously demonstrated that a deep convolutional neural network can invert the magnetic dipole kernel with a very efficient feed forward multiplication not requiring iterative optimization or the choice of regularization parameters. In this work, we extended this approach to remove background fields in QSM. The prototype method, called SHARQnet, was trained on simulated background fields and tested on 3T and 7T brain datasets. We show that SHARQnet outperforms current background field removal procedures and generalizes to a wide range of input data without requiring any parameter adjustments. In summary, we demonstrate that the solution of ill-posed problems in QSM can be achieved by learning the underlying physics causing the artifacts and removing them in an efficient and reliable manner and thereby will help to bring QSM towards clinical applications.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 31
- FWCI
- 3.14
- Field percentile
- top 9%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- DeepQSM - Using Deep Learning to Solve the Dipole Inversion for MRI Susceptibility Mapping
Steffen Bollmann, Kasper Gade Bøtker-Rasmussen, … Markus Barth·NeuroImagePeer-reviewed·Mar 29, 2019
- QSMRim-Net: Imbalance-Aware Learning for Identification of Chronic Active Multiple Sclerosis Lesions on Quantitative Susceptibility Maps
Hang Zhang, Thanh Duc Nguyen, … Elizabeth M. Sweeney·NeuroImage ClinicalPeer-reviewed·Jan 1, 2022
- QSMxT: Robust Masking and Artefact Reduction for Quantitative Susceptibility Mapping
Ashley Wilton Stewart, Simon Robinson, … Steffen Bollmann·Magnetic Resonance in MedicinePeer-reviewed·Oct 22, 2021
- The Effect of Oblique Image Acquisition on the Accuracy of Quantitative Susceptibility Mapping and a Robust Tilt Correction Method
O. C. Kiersnowski, A. Karsa, … K. Shmueli·bioRxiv·Nov 30, 2021
- QSM Reconstruction Challenge 2.0: Design and Report of Results
Berkin Bilgiç, Christian Langkammer, … Ferdinand Schweser·Magnetic Resonance in MedicinePeer-reviewed·Mar 30, 2021
- Abdominal single-step quantitative susceptibility mapping with spherical mean value filter and structure prior-based regularization
A. Abyzov, B. E. Van Beers, P. Garteiser·bioRxiv·Jul 15, 2020