Acoustic Prediction and Biomechanical Validation of Primary Stability in Uncemented Short-Stem Hip Prostheses: An In Vitro Study
Alexander JahnkeiD, Simon SchreynemackersiD, Ahmed Tawous, Swantje Petersen, Samar Hamad, Markus RickertiD, Bernd Alexander IshaqueiD
Abstract
BackgroundIn uncemented hip arthroplasty, achieving sufficient primary stability is essential for long-term implant success. However, objective intraoperative assessment of fixation quality remains challenging. Acoustic analysis of stem impaction sounds offers a promising tool for real-time evaluation, but its diagnostic accuracy and biomechanical correlation require further validation. MethodsTwelve formalin-fixed human femora were implanted with cementless Metha(R) short stems under three predefined anchorage conditions: loose, optimal (fit), and fracture-inducing press-fit. Impaction sounds were recorded using calibrated microphones and processed via frequency-domain analysis. Relative micromotions were quantified under torsional loading to biomechanically assess primary stability. ResultsSpectral markers reliably differentiated between anchorage states. The transition from loose to fit showed minimal spectral change, while fit-to-fracture was characterized by a significant increase in low-frequency energy (15 kHz). These acoustic signatures closely correlated with biomechanically measured micromotions, which showed a distinct hierarchy: fracture < fit < loose. Cluster permutation analysis confirmed statistically significant differences, particularly in the fracture group. ConclusionThis in vitro study demonstrates that frequency-based acoustic analysis can distinguish between stable, insufficient, and over-press-fit conditions during stem implantation. The findings support the potential of intraoperative acoustic monitoring as a real-time, objective tool to enhance implant safety and detect cortical compromise before it becomes clinically apparent.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 48th percentile
- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: an in vitro study
- Strategic Debulking of the Femoral Stem Promotes Load Sharing Through Controlled Flexural Rigidity of the Implant Wall: Optimization of Design by Finite Element Analysis.
Gulshan Sunavala‐Dossabhoy, Brent M. Saba, Kevin John McCarthy·bioRxiv·Jan 12, 2024
- Sound transmission by chamber prosthesis of the middle ear
W. L. Gambin·bioRxiv·Oct 23, 2020
- Why the middle ear piston prosthesis is not effective enough and how to change it?
W. L. Gambin·bioRxiv·Mar 3, 2020
- Parameterization of Proximal Humerus Locking Plate Impingement with In Vitro, In Silico, and In Vivo Techniques
E. M. Bachner, E. C. Schmidt, … M. W. Hast·bioRxiv·Jul 13, 2018
- Can force-plate measurement be trusted for balance diagnostics? Frequency-domain force-plate performance assessment for quiet-standing studies
Rika Sugimoto-Dimitrova, Jiajie Qiu, Neville Hogan·bioRxiv·Jul 8, 2026