EJNMMI ResearchNeurosciencePeer-reviewed journal article
Kinetic modeling of 18F-PI-2620 binding in the brain using an image-derived input function with total-body PET
Anjan BhattaraiiD, Emily Nicole HolyiD, Yiran WangiD, Benjamin A. SpenceriD, Guobao WangiD, Charles S DeCarliiD, Audrey Peiwen FaniD
Abstract
Accurate quantification of tau binding from 18F-PI-2620 PET requires kinetic modeling and an input function. Here, we implemented a non-invasive Image-derived input function (IDIF) derived using the state-of-the-art total-body uEXPLORER PET/CT scanner to quantify tau binding and tracer delivery rate from 18F-PI-2620 in the brain. Additionally, we explored the impact of scan duration on the quantification of kinetic parameters. Total-body PET dynamic data from 15 elderly participants were acquired. Time-activity curves from the grey matter regions of interest (ROIs) were fitted to the two-tissue compartmental model (2TCM) using a subject-specific IDIF derived from the descending aorta. ROI-specific kinetic parameters were estimated for different scan durations ranging from 10 to 90 minutes. Logan graphical analysis was also used to estimate the total distribution volume (VT). Differences in kinetic parameters were observed between ROIs, including significant reduction in tracer delivery rate (K1) in the medial temporal lobe. All kinetic parameters remained relatively stable after the 60-minute scan window across all ROIs, with K1 showing high stability after 30 minutes of scan duration. Excellent correlation was observed between VT estimated using 2TCM and Logan plot analysis. This study demonstrated the utility of IDIF with total-body PET in investigating 18F-PI-2620 kinetics in the brain.
- Citations
- 4
- FWCI
- 2.32
- Field percentile
- top 13%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In vivo characterization and quantification of neurofibrillary tau PET radioligand 18F-MK-6240 in humans from Alzheimer’s disease dementia to young controls
Tobey J. Betthauser, Karly Alex Cody, … Bradley Christian·Journal of Nuclear MedicinePeer-reviewed·May 18, 2018
- Precision measurements of brain oxygen utilization with positron emission tomography
John J. Lee, Joshua S. Shimony, … Manu S Goyal·bioRxiv·Feb 16, 2025
- Rest/Stress Myocardial Perfusion Imaging by Positron Emission Tomography with 18F-Flurpiridaz: A Feasibility Study in Mice
S. Bengs, G. I. Warnock, … A. Haider·bioRxiv·Sep 5, 2021
- caliPER: A software for blood-free parametric Patlak mapping using PET/MRI input function.
Praveen Dassanayake, Lumeng Cui, … Udunna Anazodo·bioRxiv·Jul 8, 2021
- Structural and Practical Identifiability of Dual-input Kinetic Modeling in Dynamic PET of Liver Inflammation
- External validation and time-stability analysis of STARE, a blood-free quantification tool for irreversible PET tracers
Gjertrud Louise Laurell, Elizabeth A. Bartlett, … Francesca Zanderigo·bioRxiv·Feb 11, 2026