Human Brain MappingNeurosciencePeer-reviewed journal article
The intra-individual reliability of 1H-MRS measurement in the anterior cingulate cortex across one year
Mengyun WangiD, Max KorbmacheriD, Rune EikelandiD, Alexander R. CraveniD, Karsten SpechtiD
Abstract
Magnetic resonance spectroscopy (MRS) is the primary method that can measure the levels of metabolites in the brain in vivo. To achieve its potential in clinical usage, the reliability of the measurement requires further articulation. Although there are many studies that investigate the reliability of gamma-aminobutyric acid (GABA), comparatively few studies have investigated the reliability of other brain metabolites, such as glutamate (Glu), N-acetyl-aspartate (NAA), creatine (Cr), phosphocreatine (PCr), or myo-inositol (mI), which all play a significant role in brain development and functions. In addition, previous studies which predominately used only two measurements (two datapoints) failed to provide the details of the time effect (e.g., time-of-day) on MRS measurement within subjects. Therefore, in this study, MRS data located in the anterior cingulate cortex (ACC) were repeatedly recorded across one year leading to at least 25 sessions for each subject with the aim of exploring the variability of other metabolites by using the index coefficient of variability (CV); the smaller the CV, the more reliable the measurements. We found that the metabolites of NAA, tNAA, and tCr showed the smallest CVs (between 1.61 and 4.90 %), and the metabolites of Glu, Glx, mI, and tCho showed modest CVs (between 4.26 and 7.89 %). Furthermore, we found that the concentration reference of the ratio to water with tissue correction results in smaller CVs compared to the ratio to tCr. In addition, we did not find any time-of-day effect on the MRS measurements. Collectively, the results of this study indicate that the MRS measurement is reasonably reliable in quantifying the levels of metabolites. Key pointsThe MRS measurement is reliable within subject. The ratio to water provides more reliable results compared to the ratio to tCr. The ratio to water is recommended as the internal concentration reference.
- Citations
- 9
- FWCI
- 1.48
- Field percentile
- top 20%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Testing the reliability of novel Voxel Placement approaches for Magnetic Resonance Spectroscopy
Harleen Chhabra, Melina Hehl, … Michael Burke·bioRxiv·Aug 21, 2026
- State or trait? MRS-measured GABA and Glutamate concentrations are not modulated by task demand and do not robustly predict task performance
Lotte J. Talsma, Anouk M. van Loon, … Heleen A. Slagter·bioRxiv·Feb 8, 2019
- Temporal dynamics of GABA and Glx in the visual cortex
Reuben Rideaux·eNeuroPeer-reviewed·Jun 22, 2020
- Quantitative metabolic reference for healthy human cerebrum derived from group averaged 9.4T 1H MRSI data
Andrew Martin Wright, Theresia Ziegs, A Henning·bioRxiv·Apr 4, 2024
- Benchmarking the Impact of Anatomical Segmentation on In Vivo Magnetic Resonance Spectroscopy
Jessica Archibald, Kay Chioma Igwe, … Mark E. Mikkelsen·Magnetic Resonance in MedicinePeer-reviewed·Apr 10, 2026
- Changes in brain metabolite levels across childhood
Meaghan V. Perdue, Marilena M. DeMayo, … Catherine A. Lebel·NeuroImagePeer-reviewed·Apr 18, 2023