Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney
J. Stabinska, H. J. Zollner, T. A. Thiel, H.-J. Wittsack, A. Ljimani
Abstract
PurposeTo improve the reliability of intravoxel incoherent motion model (IVIM) parameter estimation for the diffusion-weighted imaging in the kidney using a novel Image Downsampling Expedited Adaptive Least-squares (IDEAL) approach. MethodsThe robustness of IDEAL was investigated using simulated diffusion-weighted MRI data corrupted with different levels of Rician noise. Subsequently, the performance of the proposed method was tested by fitting bi- and triexponential IVIM model to in vivo renal DWI data acquired on a clinical 3 Tesla MRI scanner and compared to conventional approaches (Fixed D* and Segmented fitting). ResultsThe numerical simulations demonstrated that the IDEAL algorithm provides robust estimates of the IVIM parameters in the presence of noise as indicated by relatively low absolute percentage bias (sMdPB [%]) and normalized root-mean-square error (RMSE [%]). The analysis of the in vivo data showed that the IDEAL-based IVIM parameter maps were less noisy and more visually appealing than those obtained using the Fixed D* and Segmented methods. Further, the use of IDEAL for the triexponential IVIM modelling resulted in reduced cortical and medullary coefficients of variation (CVs) for all IVIM parameters when compared with Fixed D*, reflecting greater accuracy of this method. ConclusionThe proposed fitting algorithm yields more robust IVIM parameter estimates and is less susceptible to poor SNR than the conventional fitting approaches. Thus, the IDEAL approach has the potential to improve the reliability of renal DW-MRI analysis for clinical applications.
- organism: human
- assay: imaging
- research focus: benchmarking
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Axisymmetric diffusion kurtosis imaging with Rician bias correction: A simulation study
Jan Malte Oeschger, Karsten Tabelow, Siawoosh Mohammadi·Magnetic Resonance in MedicinePeer-reviewed·Oct 5, 2022
- Intra-voxel incoherent motion magnetic resonance imaging of the living human fetus: the technique and within-subject reproducibility
Jakab András, Ruth Tuura, … Ianina Scheer·European Radiology ExperimentalPeer-reviewed·Dec 1, 2017
- IVIM parameters have good scan-rescan reproducibility when evidential motion contaminated and poorly fitted image data are removed
O. Chevallier, N. Zhou, … Y.-X. Wang·bioRxiv·Nov 22, 2017
- On the Origins of the Cerebral IVIM Signal
Hannah V. Hare, Robert Frost, … Daniel Peter Bulte·bioRxiv·Jun 30, 2017
- Different issue types have different signal intensity on b=0 images and its implication on intravoxel incoherent motion (IVIM) analysis: examples of liver MRI
B.-H. Xiao, Y.-X. Wang·bioRxiv·Mar 11, 2021
- Nonlinear Parameter and State Estimation Approach in End-stage Kidney Disease Patients
R. Abohtyra, T. L. Vincent·bioRxiv·Apr 2, 2022