bioRxivBioengineering
The Effect of Oblique Image Acquisition on the Accuracy of Quantitative Susceptibility Mapping and a Robust Tilt Correction Method
O. C. Kiersnowski, A. Karsa, S. J. Wastling, J. S. Thornton, K. Shmueli
Abstract
PurposeQuantitative susceptibility mapping (QSM) is increasingly used for clinical research where oblique image acquisition is commonplace but its effects on QSM accuracy are not well understood. Theory and MethodsThe QSM processing pipeline involves defining the unit magnetic dipole kernel, which requires knowledge of the direction of the main magnetic field [Formula] with respect to the acquired image volume axes. The direction of [Formula] is dependent upon the axis and angle of rotation in oblique acquisition. Using both a numerical brain phantom and in-vivo acquisitions in five healthy volunteers, we analysed the effects of oblique acquisition on magnetic susceptibility maps. We compared three tilt correction schemes at each step in the QSM pipeline: phase unwrapping, background field removal and susceptibility calculation, using the root-mean-squared error and QSM-tuned structural similarity index (XSIM). ResultsRotation of wrapped phase images gave severe artefacts. Background field removal with PDF gave the most accurate susceptibilities when the field map was first rotated into alignment with [Formula]. LBV and V-SHARP background field removal methods gave accurate results without tilt correction. For susceptibility calculation, thresholded k-space division, iterative Tikhonov regularisation and weighted linear total variation regularisation all performed most accurately when local field maps were rotated into alignment with [Formula] before susceptibility calculation. ConclusionFor accurate QSM, oblique acquisition must be taken into account. Rotation of images into alignment with [Formula] should be carried out after phase unwrapping and before background field removal. We provide open-source tilt-correction code to incorporate easily into existing pipelines: https://github.com/o-snow/QSM_TiltCorrection.git.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Abdominal single-step quantitative susceptibility mapping with spherical mean value filter and structure prior-based regularization
A. Abyzov, B. E. Van Beers, P. Garteiser·bioRxiv·Jul 15, 2020
- QSMxT: Robust Masking and Artefact Reduction for Quantitative Susceptibility Mapping
Ashley Wilton Stewart, Simon Robinson, … Steffen Bollmann·Magnetic Resonance in MedicinePeer-reviewed·Oct 22, 2021
- Validation of Data Acquisition and Phase Estimation for Quantitative Susceptibility Mapping with a Rotating-Tube Phantom
K. E. Keenan, B. P. Berman, … J. Dagher·bioRxiv·Jun 29, 2021
- Investigating the Effect of Flow Compensation and Quantitative Susceptibility Mapping Method on the Accuracy of Venous Susceptibility Measurement
Ronja Berg, Christine Preibisch, … Emma Biondetti·NeuroImagePeer-reviewed·Jul 14, 2021
- The impact of coregistration of gradient recalled echo images on quantitative susceptibility and R2* mapping at 7T
S. Choi, X. Li, D. Harrison·bioRxiv·Jan 24, 2019
- SHARQnet - Sophisticated Harmonic Artifact Reduction in Quantitative Susceptibility Mapping using a Deep Convolutional Neural Network
Steffen Bollmann, Matilde Holm Kristensen, … Markus Barth·Zeitschrift für Medizinische PhysikPeer-reviewed·Feb 14, 2019