henhaobio
Sign in

Magnetic Resonance in MedicineNeurosciencePeer-reviewed journal article

QSMxT: Robust Masking and Artefact Reduction for Quantitative Susceptibility Mapping

Ashley Wilton StewartiD, Simon RobinsoniD, Kieran O’BrieniD, Jin JiniD, Georg WidhalmiD, Gilbert J. HangeliD, Angela Catherine WallsiD, Jonathan Goodwin, Korbinian EcksteiniD, Monique C. TourelliD, Catherine MorganiD, Aswin NarayananiD, Markus BarthiD, Steffen BollmanniD

PDFDOIPreprint

Abstract

PurposeQuantitative Susceptibility Mapping (QSM) is a post-processing technique applied to gradient-echo phase data. QSM algorithms require a signal mask to delineate regions with reliable phase signal for subsequent susceptibility estimation. Existing masking techniques used in QSM have limitations that introduce artefacts, exclude anatomical detail, and rely on parameter tuning and anatomical priors that narrow their application. Here, a robust masking and reconstruction procedure is presented to overcome these limitations and enable automated QSM processing for a wide range of use-cases implemented in an open-source software framework: QSMxT. MethodsA robust masking technique that automatically separates reliable from less reliable phase regions was developed and combined with a two-pass reconstruction procedure that operates on the separated sources before combination, extracting more information while reducing the influence of artefacts. ResultCompared with standard masking and reconstruction procedures, the two-pass inversion reduces streaking artefacts caused by unreliable phase and high dynamic ranges of susceptibility sources. QSMxT is robust across a range of datasets at 3 T in healthy volunteers and phantoms, at 7 T in tumour patients, and in the QSM challenge 2.0 simulated brain dataset, with significant artefact and error reductions, greater anatomical detail, and minimal parameter tuning. ConclusionQSMxT generates masks for QSM that separate reliable from less reliable phase regions, enables a more accurate QSM reconstruction that mitigates artefacts, operates without anatomical priors, and requires minimal parameter tuning. QSMxT makes QSM processing more accessible, reliable and reproducible.

Citations
39
FWCI
2.11
Field percentile
top 13%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISAbyzov '20Kiersnowski '21Keenan '21Marques '21Bilgiç '21Chan '20
78% semantic matchPathology
A. Abyzov, B. E. Van Beers, P. Garteiser·bioRxiv·Jul 15, 2020