bioRxivNeurosciencePreprint
Characterization of b-value dependent T2 relaxation rates for probing neurite microstructure
Abstract
Brain tissue microstructure is characterized by heterogeneous diffusivity and transversal relaxation rates. Standard diffusion MRI (dMRI) is acquired using a single echo time (TE) and only provides information about heterogeneous diffusivity in the underlying tissue. Combined relaxation diffusion MRI (rdMR) integrates dMRI with multiple TEs to probe the coupling between relaxation rate and diffusivity. This work introduces a method to model rdMRI data signals by characterizing the apparent relaxation rate related to dMRI with different b-values. The proposed approach can extrapolate dMRI signals to ultra-long or ultra-short TEs to increase or reduce signals from intra-neurite water to improve the characterization of neurite microstructure without solving multi-compartment models. The performance of the proposed method was examined using an in vivo dataset acquired from a clinical scanner to estimate neurite sizes.
- Citations
- 3
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Joint RElaxation-Diffusion Imaging Moments (REDIM) to probe neurite microstructure
Lipeng Ning, Borjan A. Gagoski, … Yogesh Rathi A·IEEE Transactions on Medical ImagingPeer-reviewed·Aug 8, 2019
- Time-division multiplexing (TDM) sequence removes bias in T2 estimation and relaxation-diffusion measurements
Qiang Liu, Borjan A. Gagoski, … Lipeng Ning·Magnetic Resonance in MedicinePeer-reviewed·Aug 13, 2024
- In vivo disentanglement of diffusion frequency-dependence, tensor shape, and relaxation using multidimensional MRI
Jessica T. E. Johnson, Mustafa Okan Irfanoglu, … Dan Benjamini·Human Brain MappingPeer-reviewed·May 1, 2024
- Linking microscopy to diffusion MRI with degenerate biophysical models: an application of the Bayesian EstimatioN of CHange (BENCH) framework
Daniel Kor, Hossein Rafipoor, … Amy F.D. Howard·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- A multi-b-value test-retest diffusion MRI brain dataset for model validation and reproducibility assessment
Tomasz Pieciak, Irene Guadilla, … Antonio Tristán‐Vega·bioRxiv·Aug 27, 2026
- Optimisation and Pre-clinical Demonstration of Temporal Diffusion Ratio for Imaging Restricted Diffusion
W. Warner, M. Palombo, … I. Drobnjak·bioRxiv·Jul 25, 2022