Magnetic Resonance in MedicineNeurosciencePeer-reviewed journal article
Time-division multiplexing (TDM) sequence removes bias in T2 estimation and relaxation-diffusion measurements
Qiang LiuiD, Borjan A. GagoskiiD, Imam Ahmed ShaikiD, Carl‐Fredrik WestiniD, Elisabeth A. WildeiD, Walter SchneideriD, Berkin BilgiçiD, William A. GrissomiD, Jon‐Fredrik NielseniD, Maxim ZaitseviD, Yogesh Rathi AiD, Lipeng NingiD
Abstract
PurposeTo compare the performance of multi-echo (ME) and time-division multiplexing (TDM) sequences for accelerated relaxation-diffusion MRI (rdMRI) acquisition and to examine their reliability in estimating accurate rdMRI microstructure measures. MethodThe ME, TDM, and the reference single-echo (SE) sequences with six echo times (TE) were implemented using Pulseq with single-band (SB-) and multi-band 2 (MB2-) acceleration factors. On a diffusion phantom, the image intensities of the three sequences were compared, and the differences were quantified using the normalized root mean squared error (NRMSE). For the in-vivo brain scan, besides the image intensity comparison and T2-estimates, different methods were used to assess sequence-related effects on microstructure estimation, including the relaxation diffusion imaging moment (REDIM) and the maximum-entropy relaxation diffusion distribution (MaxEnt-RDD). ResultsTDM performance was similar to the gold standard SE acquisition, whereas ME showed greater biases (3-4x larger NRMSEs for phantom, 2x for in-vivo). T2 values obtained from TDM closely matched SE, whereas ME sequences underestimated the T2 relaxation time. TDM provided similar diffusion and relaxation parameters as SE using REDIM, whereas SB-ME exhibited a 60% larger bias in the map and on average 3.5x larger bias in the covariance between relaxation-diffusion coefficients. ConclusionOur analysis demonstrates that TDM provides a more accurate estimation of relaxation-diffusion measurements while accelerating the acquisitions by a factor of 2 to 3.
- Citations
- 6
- FWCI
- 1.53
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Optimisation and Pre-clinical Demonstration of Temporal Diffusion Ratio for Imaging Restricted Diffusion
W. Warner, M. Palombo, … I. Drobnjak·bioRxiv·Jul 25, 2022
- MESMERISED: Super-accelerating T1 relaxometry and diffusion MRI with STEAM at 7 T for quantitative multi-contrast and diffusion imaging
Francisco J. Fritz, Benedikt Andreas Poser, Alard F. Roebroeck·NeuroImagePeer-reviewed·Jun 17, 2021
- Characterization of b-value dependent T2 relaxation rates for probing neurite microstructure
Lipeng Ning, Carl‐Fredrik Westin, Yogesh Rathi A·bioRxiv·Sep 2, 2022
- Improving the reliability of T2 measurement in magnetic resonance imaging
Xiuli Yang·bioRxiv·Jun 9, 2024
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions
Cornelius Eichner, Michael Paquette, … Alfred Anwander·NeuroImagePeer-reviewed·Jul 15, 2020
- Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T