Magnetic resonance spectroscopy (MRS) is a non-invasive neuroimaging technique used to measure brain chemistry in vivo and has been used to study the healthy brain as well as neuropathology in numerous neurological disorders. The number of multi-site studies using MRS are increasing; however, non-biological variability introduced during data collection across multiple sites, such as differences in scanner vendors and site-specific acquisition implementations for MRS, can obscure detection of biological effects of interest. ComBat is a data harmonisation technique that can remove non-biological sources of variance in multisite studies. It has been validated for use with structural and functional MRI metrics but not for MRS metabolites. This study investigated the validity of using ComBat to harmonize MRS metabolites for vendor and site differences. Analyses were performed using data acquired across 20 sites and included edited MRS for GABA+ (N=218) and macromolecule-suppressed GABA data (N=209), as well as standard PRESS data to quantify NAA, creatine, choline, and glutamate (N=195). ComBat harmonisation successfully mitigated vendor and site differences for all metabolites of interest. Moreover, significant associations were detected between sex and choline levels and between age and glutamate and GABA+ levels that were not detectable prior to harmonisation, confirming the importance of removing site and vendor effects in multi-site data. In conclusion, ComBat harmonisation can be successfully applied to MRS data in multi-site MRS studies. HighlightsO_LIMulti-site MRS data contains sources of non-biological variance that can mask biological effects of interest. C_LIO_LIComBat data harmonisation successfully removes variance contributed by scanner and site differences. C_LIO_LIRemoval of this variance revealed biological effects that were previously not detected. C_LIO_LIComBat harmonisation can be successfully applied to MRS data in multi-site MRS studies C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.69
- Field percentile
- top 30%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Exploring the limits of ComBat method for multi-site diffusion MRI harmonization
Suheyla Cetin Karayumak, Katharina Stegmayer, … Yogesh Rathi A·bioRxiv·Nov 20, 2020
- More than half of the variance in in-vivo 1H-MRS metabolite estimates is common to all metabolites
James J. Prisciandaro, Helge J. Zöllner, … Richard A.E. Edden·bioRxiv·Sep 29, 2022
- MM-ComBat and MM-CovBat: Multivariate Frameworks for Joint Harmonization of Multi-Metric Neuroimaging Data
Zheng Ren, Patrick S. Sadil, Martin A. Lindquist·bioRxiv·May 14, 2026
- ComBatLS: A location- and scale-preserving method for multi-site image harmonization
Margaret Gardner, Russell Taki Shinohara, … Andrew A. Chen·Human Brain MappingPeer-reviewed·Jun 1, 2025
- Testing the reliability of novel Voxel Placement approaches for Magnetic Resonance Spectroscopy
Harleen Chhabra, Melina Hehl, … Michael Burke·bioRxiv·Aug 21, 2026
- Spatiospectral image processing workflow considerations for advanced MR spectroscopy of the brain
L. Y. Cai, S. N. Del Tufo, … B. A. Landman·bioRxiv·Sep 7, 2023