Mathematics and visualizationNeurosciencePeer-reviewed journal article
Deep learning model fitting for diffusion-relaxometry: a comparative study
Francesco GrussuiD, Marco BattistoniD, Marco PalomboiD, Torben SchneideriD, Claudia A. M. Gandini Wheeler‐KingshottiD, Daniel C. AlexanderiD
- Citations
- 26
- FWCI
- 17.21
- Field percentile
- top 1%
Abstract
Quantitative Magnetic Resonance Imaging (qMRI) signal model fitting is traditionally performed via non-linear least square (NLLS) estimation. NLLS is slow and its performance can be affected by the presence of different local minima in the fitting objective function. Recently, machine learning techniques, including deep neural networks (DNNs), have been proposed as robust alternatives to NLLS. Here we present a deep learning implementation of qMRI model fitting, which uses DNNs to perform the inversion of the forward signal model. We compare two DNN training strategies, based on two alternative definitions of the loss function, since at present it is not known which definition leads to the most accurate, precise and robust parameter estimation. In strategy 1 we define the loss as the l2-norm of tissue parameter prediction errors, while in strategy 2 as the l2-norm of MRI signal prediction errors. We compare the two approaches on synthetic and 3T in vivo saturation inversion recovery (SIR) diffusion-weighted (DW) MRI data, using a model for joint diffusion-T1 mapping. Strategy 1 leads to lower tissue parameter root mean squared errors (RMSEs) when realistic noise distributions are considered (e.g. Rician vs Gaussian). However, strategy 2 offers lower signal reconstruction RMSE, and allows training to be performed on both synthetic and actual in vivo MRI measurements. In conclusion, both strategies are valid choices for DNN-based fitting. Strategy 2 is more practical, as it does not require pre-computation of reference tissue parameters, but may lead to worse parameter estimation.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Neural Networks for parameter estimation in microstructural MRI: a study with a high-dimensional diffusion-relaxation model of white matter microstructure
João P. de Almeida Martins, Markus Nilsson, … Filip Szczepankiewicz·NeuroImagePeer-reviewed·Sep 22, 2021
- Training Data Distribution Significantly Impacts the Estimation of Tissue Microstructure with Machine Learning
Noemi G. Gyori, Marco Palombo, … Daniel C. Alexander·Magnetic Resonance in MedicinePeer-reviewed·Sep 21, 2021
- DeepQSM - Using Deep Learning to Solve the Dipole Inversion for MRI Susceptibility Mapping
Steffen Bollmann, Kasper Gade Bøtker-Rasmussen, … Markus Barth·NeuroImagePeer-reviewed·Mar 29, 2019
- Simulation-Based Inference at the Theoretical Limit: Fast, Accurate Microstructural MRI with Minimal diffusion MRI Data
Maximilian F. Eggl, Silvia De Santis·bioRxiv·Nov 11, 2024
- Streamlined Magnetic Resonance Fingerprinting: Fast Whole-brain Coverage with Deep-learning Based Parameter Estimation
Mahdi Khajehim, Thomas Christen, … Simon J. Graham·NeuroImagePeer-reviewed·Jun 5, 2021
- SHARQnet - Sophisticated Harmonic Artifact Reduction in Quantitative Susceptibility Mapping using a Deep Convolutional Neural Network
Steffen Bollmann, Matilde Holm Kristensen, … Markus Barth·Zeitschrift für Medizinische PhysikPeer-reviewed·Feb 14, 2019