henhaobio
Sign in

Frontiers in MicrobiologyBioinformaticsPeer-reviewed journal article

Using QC-Blind for quality control and contamination screening of bacteria DNA sequencing data without reference genome

Xi WangiD, Yan GaoiD, Zhangyu ChengiD, Chaoyun CheniD, Maozhen HaniD, Pengshuo YangiD, Guangzhou XiongiD, Kang NingiD

PDFDOIPreprint

Abstract

Quality control in next generation sequencing has become increasingly important as the technique becomes widely used. Tools have been developed for filtering possible contaminants in the sequencing data of species with known reference genome. Unfortunately, reference genomes for all the species involved, including the contaminants, are required for these tools to work. This precludes many real-life samples that have no information about the complete genome of the target species, and are contaminated with unknown microbial species.\n\nIn this work we propose QC-Blind, a novel quality control pipeline for removing contaminants without any use of reference genomes. The pipeline requires only very little information from the marker genes of the target species. The entire pipeline consists of unsupervised read assembly, contig binning, read clustering and marker gene assignment.\n\nWhen evaluated on in silico, ab initio and in vivo datasets, QC-Blind proved effective in removing unknown contaminants with high specificity and accuracy, while preserving most of the genomic information of the target bacterial species. Therefore, QC-Blind could serve well in situations where limited information is available for both target and contamination species.\n\nIMPORTANCEAt present, many sequencing projects are still performed on potentially contaminated samples, which bring into question their accuracies. However, current reference-based quality control method are limited as they need either the genome of target species or contaminations. In this work we propose QC-Blind, a novel quality control pipeline for removing contaminants without any use of reference genomes. When evaluated on in silico, ab initio and in vivo datasets, QC-Blind proved effective in removing unknown contaminants with high specificity and accuracy, while preserving most of the genomic information of the target bacterial species. Therefore, QC-Blind is suitable for real-life samples where limited information is available for both target and contamination species.

Citations
10
FWCI
0.33
Field percentile
top 48%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISKlingenberg '21Cornet '18Lataretu '25CHALLIS '20Goig '20Orakov '21
59% semantic matchBioinformatics
Heiner Klingenberg, Peter Meinicke·bioRxiv·Oct 1, 2021