Optics ExpressBiophysicsPeer-reviewed journal article
Absorption dipole effects on MINFLUX single molecule localization
Abstract
Single molecule fluorescence localization with minimum photon flux imaging (MINFLUX) can achieve localization precisions in the small nanometer range or better under suitable conditions. Potentially adverse conditions, such as a fixed fluorescence dipole or optical aberrations, that could cause systematic localization errors, have received little attention up to now. Here, we study these effects in simulation. We find that biases occur for fluorophores with a fixed absorption dipole tilted out of the imaging plane. These become larger (up to about 25% of the diameter of the circle spanned by the doughnut center positions) the larger the tilt angle gets. As a rule of thumb the spread in bias is smaller than 5 nm in case the dipole orientation is less than 30{degrees} out of plane for the typical case of a doughnut probing circle of diameter 100 nm. For freely rotating dipoles only the primary aberrations astigmatism and coma contribute to bias. This bias depends on the position of the fluorophore inside the circular probing area of MINFLUX and can be significantly larger than the localization precision. We show that increasing the number of measurements over the circle from a triangular to a hexagonal pattern is beneficial for reducing bias in all cases. Iterative shrinking of the probing area can eliminate the position dependent bias completely, but a strong dependence on dipole orientation of the bias at the center of the probing area remains.
- Citations
- 1
- FWCI
- 2.76
- Field percentile
- top 14%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Near-infrared MINFLUX imaging enabled by suppression of fluorophore blinking
Chinmaya Venugopal Srambickal, Hanie M Esmaeeli, … Jerker Widengren·Science AdvancesPeer-reviewed·Dec 5, 2025
- Localization accuracy in single-molecule fluorescence microscopy
Katarina B. Chapman, Roman Schmidt, … Stefan W. Hell·bioRxiv·Oct 16, 2026
- ISM-FLUX: MINFLUX with an array detector
E. Slenders, G. Vicidomini·bioRxiv·Apr 19, 2022
- Array Detection Enables Large Localization Range for Simple and Robust MINFLUX
Eli Slenders, Sanket Patil, … Giuseppe Vicidomini·Light Science & ApplicationsPeer-reviewed·Jul 3, 2025
- 4Pi MINFLUX arrangement maximizes spatio-temporal localization precision of fluorescence emitter
J. Rickert, M. O. Held, … S. W. Hell·bioRxiv·Oct 30, 2023
- Localization microscopy at doubled precision with patterned illumination
Jelmer P. Cnossen, Taylor A. Hinsdale, … Sjoerd Stallinga·Nature MethodsPeer-reviewed·Dec 9, 2019