Sign in
BioengineeringBiomedical Optics Express
Peer-reviewed journal article

On-skin, micro-objective enabled camera module for speckle contrast optical spectroscopy/tomography

Andrés QuirogaiD, Lorenzo CorteseiD, Manish VermaiD, Peter DannbergiD, Ilias TachtsidisiD, Norbert DanziD, Turgut DurduraniD

Abstract

In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 micro-objetives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio (>4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers
Citations
2
FWCI
1.16
Field percentile
top 23%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.