bioRxivBioinformaticsPreprint
Bravais Lattice Sampling: Geometry-Guided Sparse Probing for Connected-Component Detection in 3D Discretized Spaces
Abstract
We introduce Bravais Lattice Sampling (BLS), a two-phase method for detecting connected high-density regions in three-dimensional space. BLS places probe sites on a Bravais lattice scaled to the expected nearest-neighbour distance dNN of the target structures, then recovers cluster boundaries by depth-first expansion seeded only from occupied probes, replacing the exhaustive raster scan that conventional connected-component labelling uses to discover seeds. The spacing between probe sites is set from the covering radius of the lattice, which is what allows the method to state in advance the size below which a cluster may escape detection. The second phase, an expansion refinement activated only on probes that return an occupied voxel, verifies every edge, so the components returned are true connected components. BLS versatility allows for selection of different Bravais lattice unit cells to match the target structure; for amorphous, non-crystalline shapes, BLS can default to a simple face-centred cubic unit cell, where the expected minimum cluster size is the only parameter that needs to be set. The current BLS implementation has been developed as a post-processing tool for molecular dynamics trajectories, and was tested for searching water ice clusters of different morphologies. BLS returns component counts and maximum cluster sizes identical to exhaustive-labeller algorithms, with 100% recall; it runs at about 0.94 times the cost of depth-first search, and at 0.84 to 0.90 times the cost of the fastest other labeller in our benchmark set. This algorithm, although implemented by us for molecular dynamics applications, could be of interest in other domain areas where searching for high-density elements in 3D space is relevant.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- FOCAL3D: A 3-dimensional clustering package for single-molecule localization microscopy
Daniel F. Nino, Daniel Djayakarsana, Joshua N. Milstein·PLoS Computational BiologyPeer-reviewed·Dec 8, 2020
- To slide or not to slide, that is the question: evaluating dense semilandmarks and sliding in 3D geometric morphometrics with real and simulated data
A. Murat Maga·bioRxiv·Aug 28, 2026
- Multithreaded two-pass connected components labelling and particle analysis in ImageJ
Michael Doube·Royal Society Open SciencePeer-reviewed·Mar 1, 2021
- Density-based optimization for unbiased, reproducible clustering applied to single molecule localization microscopy
Joseph L. Hammer, Alexander J. Devanny, Laura J. Kaufman·Communications BiologyPeer-reviewed·Jun 10, 2025
- Broadband backscattering confocal microscopy enables label-free 3D live cell nanoscale sensitive imaging
Mark F. Coughlan, Lei Zhang, … Lev T. Perelman·Science AdvancesPeer-reviewed·Sep 16, 2026
- High-performance analysis of biomolecular containers to measure small-molecule transport, transbilayer lipid diffusion, and protein cavities
A. J. Bryer, J. A. Hadden, … J. R. Perilla·bioRxiv·Jul 13, 2019