bioRxivBioengineeringPreprint
Receive-Only Coupled Wireless Radiofrequency Probe for Endocavity MR Imaging Using a pTx System
Akbar AlipouriD, Volkan AçıkeliD, Sayım GökyariD, Oktay AlgıniD, Çağdaş OtoiD, Priti BalchandaniiD, Hilmi Volkan DemiriD, Ergin AtalariD
Abstract
PurposeTo enhance the SNR in MRI within a localized region of interest using a novel interventional wireless RF resonator probe combined with a dual-drive pTx system. MethodsA dual-drive body birdcage coil was operated in a linearly-polarized mode to decouple a passive RF resonator probe from the transmit field while maintaining the resonator in a receive-only coupled mode. The resonator was fabricated using standard microfabrication techniques and tuned to the Larmor frequency of a 3T MRI system. The 10-g specific absorption rate (SAR) distribution was simulated to identify potential hot spots around the resonator prior to heating experiments. To evaluate the interaction between the resonator probe and the linearly-polarized transmit field, SNR and flip-angle distributions were measured in a phantom. In vivo imaging studies were subsequently performed using the resonator probe in conjunction with the linearly-polarized dual-drive birdcage coil. ResultsTemperature measurements demonstrated a normalized temperature increase of less than 0.10{degrees}C, corresponding to a SAR value below 1.21 W/kg. Experimental flip-angle mapping confirmed effective magnetic decoupling of the resonator probe using linearly-polarized dual-drive transmission. An SNR enhancement factor of 1.6 was achieved within the region of interest in phantom experiments. In vivo imaging demonstrated a 2.0 {+/-} 0.2-fold SNR enhancement in the vicinity of the resonator probe. ConclusionA novel interventional approach for localized SNR enhancement in MRI was demonstrated using a wireless RF resonator probe and a dual-drive pTx system. The proposed technique enables local signal enhancement while minimizing transmit-field interactions, thereby facilitating safe interventional MRI and potentially improving image quality and diagnostic performance.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
K. M. Gilbert, P. Dubovan, … C. A. Baron·bioRxiv·Sep 27, 2021
- RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5 Tesla
Matt Waks, Russell Lagore, … Kǎmil Uǧurbil·bioRxiv·May 23, 2024
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants
L. Golestanirad, B. Keil, … L. L. Wald·bioRxiv·Nov 22, 2018
- Focal fMRI signal enhancement with implantable inductively coupled detectors
Yi Chen, Qi Wang, … Xin Yu·NeuroImagePeer-reviewed·Dec 8, 2021
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T
E. Kazemivalipour, A. Sadeghi-Tarakameh, … L. G. Rad·bioRxiv·Dec 13, 2022
- A 128-channel receive array with enhanced SNR performance for 10.5 tesla brain imaging
Russell Lagore, Alireza Sadeghi‐Tarakameh, … Kǎmil Uǧurbil·bioRxiv·Oct 20, 2024