Imaging NeuroscienceNeurosciencePeer-reviewed journal article
Strategies for motion- and respiration-robust estimation of fMRI intrinsic neural timescales
Andrew Goldberg, Isabella Rosario, Jonathan D. PoweriD, Guillermo HorgaiD, Kenneth WengleriD
Abstract
Intrinsic neural timescale (INT) is a resting-state fMRI (rs-fMRI) measure that reflects the time window of neural integration within a brain region. Despite the potential relevance of INT to cognition, brain organization, and neuropsychiatric illness, the influences of physiological artifacts on INT have not been systematically considered. Two artifacts, head motion and respiration, pose serious issues in rs-fMRI studies. Here, we described their impact on INT estimation and tested the ability of two denoising strategies for mitigating these artifacts, high-motion frame censoring and global signal regression (GSR). We used a subset of the HCP Young Adult dataset with runs annotated for breathing patterns (Lynch et al., 2020) and at least one "clean" (reference) run that had minimal head motion and no respiration artifacts; other runs from the same participants (n = 46) were labeled as "non-clean." We found that non-clean runs exhibited brain-wide increases in INT compared to their respective clean runs and the magnitude of error in INT between non-clean and clean runs correlated with the amount of head motion. Importantly, effect sizes were comparable to INT effects reported in the clinical literature. GSR and high-motion frame censoring improved the similarity between INT maps from non-clean runs and their respective clean run. Using a pseudo-random frame-censoring approach, there was a relationship between the amount of censored frames and both the mean INT and mean error, suggesting that frame censoring itself biases INT estimation. A group-level correction procedure reduced this bias and improved similarity between non-clean runs and their respective clean run. Based on our findings, we offer recommendations for rs-fMRI INT studies, which include implementing GSR and high-motion frame censoring with Lomb-Scargle interpolation of censored data, and performing group-level correction of the bias introduced by frame censoring.
- assay: imaging
- research focus: benchmarking
- research focus: dimensionality reduction
- approach: statistical model
- approach: experimental assay
- Citations
- 2
- FWCI
- 0.49
- Field percentile
- top 39%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Correction of respiratory artifacts in MRI head motion estimates
Damien A. Fair, Óscar Miranda-Domínguez, … Nico U.F. Dosenbach·NeuroImagePeer-reviewed·Nov 25, 2019
- Resting state global brain activity induces bias in fMRI motion estimates
Yixiang Mao, Conan Chen, … Thomas T. Liu·Imaging NeurosciencePeer-reviewed·Apr 12, 2024
- A Hilbert-based method for processing respiratory timeseries
Samuel J. Harrison, Samuel Bianchi, … Lars Kasper·NeuroImagePeer-reviewed·Jan 28, 2021
- An evaluation of the efficacy, reliability, and sensitivity of motion correction strategies for resting-state functional MRI
Linden Parkes, Ben Fulcher, … Alex Fornito·NeuroImagePeer-reviewed·Dec 24, 2017
- Distinctions among real and apparent respiratory motions in human fMRI data
Jonathan D. Power, Charles J. Lynch, … Rebecca Merrill Jones·NeuroImagePeer-reviewed·Jul 22, 2019
- Estimating fMRI Timescale Maps
Gabriel Riegner, Samuel Davenport, … Armin Schwartzman·Imaging NeurosciencePeer-reviewed·Jan 1, 2026