bioRxivNeurosciencePreprint
MRI-free OPM-MEG recovers medial temporal lobe theta during scene imagination
Conor ThornberryiD, Prathiksha MathiD, Margarida Cohen Serra, Robert A. SeymouriD, Clodagh NolaniD, Robert WhelaniD
Abstract
Optically pumped magnetometer magnetoencephalography (OPM-MEG) offers a wearable, movement-tolerant alternative to conventional cryogenic MEG, placing sensors closer to the scalp and, in principle, improving sensitivity to deep sources. This is advantageous for examining subcortical structures that are affected by ageing, disorders and disease, such as the hippocampus. However, it remains unclear whether well-established activity (such as the attenuation of theta oscillations during the imagination of novel scenes) can be recovered from the medial temporal lobe (MTL) with OPM-MEG, and whether an individual structural MRI is required. Here, fifteen adults completed a scene imagination task. Initially we applied a 12-parameter template warping coregistration pipeline to the full sample. Following source reconstruction, we recovered the expected attenuation of theta (4-8 Hz) power during scene imagination compared to a counting baseline, with a significant cluster of activity peaking in the left parahippocampal gyrus. The clusters centre of mass was localised to the left hippocampus (t = -3.55, p = 0.048, whole-brain FWE-corrected) and was mostly confined to the left medial temporal lobe. We further supported our findings by using an individual T1-weighted MRI reconstruction pipeline in six participants who had these scans available. The two approaches produced similar whole-brain topographies and localised the peak MTL theta effect to left hippocampus, with temporal-lobe conjunction centroids 3-mm apart. These findings provide evidence that the theta attenuation of the scene construction network can be recovered at the group level with OPM-MEG, without an individual MRI.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Source Reconstruction Without an MRI using Optically Pumped Magnetometer based Magnetoencephalography
Natalie Rhodes, Lukas Rier, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Wearable magnetoencephalography in an open environment
Fufu Zheng, Congcong Li, … Jia‐Hong Gao·bioRxiv·Jul 31, 2026
- Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Ryan M. Hill, Elena Boto, … Matthew J. Brookes·NeuroImagePeer-reviewed·May 29, 2020
- Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm
Olivia R. Christiano, Sebastian Michelmann·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Intracranial Validation of Magnetoencephalography Across Oscillatory Frequency and Depth
Chetan Gohil, George C. O’Neill, … Umesh Vivekananda·bioRxiv·Aug 23, 2026