Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm
Abstract
Optically pumped magnetometers (OPMs) offer a promising advancement in noninvasive neuroimaging via magnetoencephalography (MEG), but establishing their reliability and comparability to existing methods remains an ongoing endeavor. Here, we evaluated OPM recordings by assessing their test-retest reliability and comparing them to functional magnetic resonance imaging (fMRI) and intracranial electroencephalography (iEEG) recordings. Data were collected from three independent participant groups during repeated viewings of a movie segment. In 7 canonical frequency bands ({delta}: 0.5-4 Hz,{theta} : 4-8 Hz, : 8-12 Hz, {beta}: 12-28 Hz,{gamma} 1: 28-46 Hz,{gamma} 2: 55-70 Hz, and HF: 64-116 Hz), as well as a broadband (BB: 0.5-116 Hz) signal, we quantified the signal consistency (1) within individuals, (2) across subjects, and (3) across modalities. OPM exhibited widespread reliability, particularly in lower frequency bands; spatial patterns resembled those of fMRI and iEEG in visual and auditory regions. Cross-modal analyses revealed robust correspondence between OPM and both fMRI and iEEG, including inverse correlations at low frequencies and positive correlations at higher frequencies in the OPM-fMRI comparison, consistent with known relationships between oscillatory power and BOLD responses. Comparisons of signal-to-noise (SNR) estimates further revealed that in some regions, the SNR of cross-modal alignment exceeded within-modality reliability, suggesting that bridging between modalities can sometimes enhance SNR by attenuating reliably shared noise. Our findings demonstrate that OPM consistently captures stimulus-locked neural dynamics that converge with established modalities.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 22th percentile
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Test-Retest Reliability of the Human Connectome: An OPM-MEG study
Lukas Rier, Sebastian Michelmann, … Elena Boto·Imaging NeurosciencePeer-reviewed·Sep 13, 2023
- Test-retest reliability of auditory MMN measured with OPM-MEG
László Demkó, Sandra Iglesias, … Klaas Enno Stephan·bioRxiv·Dec 10, 2024
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022
- OPM quantum sensors enhance non-invasive neuroimaging performance
Marion Brickwedde, Paul Anders, … Peter J. Uhlhaas·bioRxiv·May 30, 2025
- Improved spatio-temporal measurements of visually evoked fields using optically-pumped magnetometers
Aikaterini Gialopsou, C. Abel, … P. Krüger·Scientific ReportsPeer-reviewed·Nov 17, 2021