Artificial OrgansBioengineeringPeer-reviewed journal article
The Effect of Blood Viscosity on Shear-Induced Hemolysis using a Magnetically Levitated Shearing Device
Abstract
IntroductionBlood contacting medical devices, including rotary blood pumps, can cause shear-induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell-scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). MethodsWe empirically investigated hemolysis in an axial Couette flow device typical of a rotary VAD to expand our current understanding of shear-induced blood damage in two ways. First, we used a magnetically levitated device to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Second, we explored the effects of both hematocrit and plasma viscosity on shear-induced hemolysis to characterize blood damage based on the viscosity-independent shear rate, rather than on shear stress. ResultsOver a shear rate range of 20,000-80,000 1/s, the Index of Hemolysis was found to be largely independent of hematocrit, bulk viscosity, or the suspension media viscosity. ConclusionIt is recommended that future investigations of shear-induced blood damage report findings with respect to the viscosity-neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Remodeled cephalic arch geometry promotes disturbed flow at pre-maturation flow rates in hemodialysis patients
Dylan Cook, Sanjeev S. Dhara, … Mary S. Hammes·bioRxiv·Jul 27, 2026
- Empirical and Computational Evaluation of Hemolysis in a Microfluidic Extracorporeal Membrane Oxygenator (ECMO) Prototype
N. Imtiaz, M. D. Poskus, … S. W. Day·bioRxiv·Jun 15, 2020
- Fluid-structure interaction simulation of tissue degradation and its effects on intra-aneurysm hemodynamics
H. Wang, K. Uhlmann, … F. Varnik·bioRxiv·Sep 1, 2021
- Mechanical Stimuli such as Shear Stress and Piezo1 Stimulation Generate Red Blood Cell Extracellular Vesicles
G. S. Sangha, C. M. Weber, … A. M. Clyne·bioRxiv·Oct 4, 2022
- Marginated aberrant red blood cells induce pathologic vascular stress fluctuations in a computational model of hematologic disorders
X. Cheng, C. Caruso, … M. D. Graham·bioRxiv·May 16, 2023
- Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework
Tianai Wang, Christine Quast, … Michael Neidlin·PLoS Computational BiologyPeer-reviewed·Mar 27, 2025