Validating Pore Size Estimates in a Complex Microfibre Environment on a Human MRI System
C.-C. Huang, C.-C. H. Hsu, F.-L. Zhou, S. Kusmia, M. Drakesmith, G. J. M. Parker, C.-P. Lin, D. K. Jones
Abstract
PurposeRecent advances in diffusion-weighted MRI provide restricted diffusion signal fraction and restricting pore size estimates. Materials based on co-electrospun oriented hollow cylinders have been introduced to provide validation for such methods. This study extends this work, exploring accuracy and repeatability using an extended acquisition on a 300 mT/m gradient human MRI scanner, in substrates closely mimicking tissue, i.e., non-circular cross-sections, intra-voxel fibre crossing, intra-voxel distributions of pore-sizes and smaller pore-sizes overall. MethodsIn a single-blind experiment, diffusion-weighted data were collected from a biomimetic phantom on a 3T Connectom system using multiple gradient directions/diffusion times. Repeated scans established short-term and long-term repeatability. The total scan time (54 minutes) matched similar protocols used in human studies. The number of distinct fibre populations was estimated using spherical deconvolution, and median pore size estimated through the combination of CHARMED and AxCaliber3D framework. Diffusion-based estimates were compared with measurements derived from scanning electron microscopy. ResultsThe phantom contained substrates with different orientations, fibre configurations and pore size distributions. Irrespective of one or two populations within the voxel, the pore-size estimates (~5m) and orientation-estimates showed excellent agreement with the median values of pore-size derived from scanning electron microscope and phantom configuration. Measurement repeatability depended on substrate complexity, with lower values seen in samples containing crossing-fibres. Sample-level repeatability was found to be good. ConclusionWhile no phantom mimics tissue completely, this study takes a step closer to validating diffusion microstructure measurements for use in vivo by demonstrating the ability to quantify microgeometry in relatively complex configurations.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Novel Pore Size-Controlled, Susceptibility Matched, 3D-Printed MRI Phantoms
V. Witherspoon, M. E. Komlosh, … P. Basser·bioRxiv·Oct 10, 2022
- Microstructural characterization and validation of a 3D printed axon-mimetic phantom for diffusion MRI
Farah N. Mushtaha, Tristan K. Kuehn, … Ali R. Khan·bioRxiv·Jul 2, 2020
- Does powder averaging remove dispersion bias in diffusion MRI diameter estimates within real 3D axonal architectures?
Mariam Andersson, Marco Pizzolato, … Tim B. Dyrby·NeuroImagePeer-reviewed·Nov 9, 2021
- SPHERIOUSLY? The challenges of estimating spherical pore size non-invasively in the human brain from diffusion MRI
Maryam Afzali, Markus Nilsson, … Derek Kenton Jones·NeuroImagePeer-reviewed·May 19, 2021
- Electron microscopy 3-dimensional segmentation and quantification of axonal dispersion and diameter distribution in mouse brain corpus callosum
Hong‐Hsi Lee, Katarina Yaros, … Els Fieremans·Brain Structure and FunctionPeer-reviewed·Feb 21, 2019
- Enabling complex fibre geometries using 3D printed axon-mimetic phantoms
Tristan K. Kuehn, Farah N. Mushtaha, … Corey Allan Baron·Frontiers in NeurosciencePeer-reviewed·Apr 7, 2022