Apparent Propagator Anisotropy from reduced Diffusion MRI acquisitions
Santiago Aja‐FernándeziD, Antonio Tristán‐VegaiD, Derek Kenton JonesiD
Abstract
The Propagator Anisotropy (PA) is a measurement of the orientational variability inside a tissue estimated from diffusion MRI using the Ensemble Average diffusion Propagator (EAP). It is based on the quantification of the angular difference between the propagator in a specific voxel and its isotropic counterpart. The PA has shown the ability to reveal microstructural information of interest and meaningful descriptive maps inside the white matter. However, the use of PA is not generalized among the clinical community, due to the great amount of data needed for its calculation, together with the associated long processing times. In order to calculate the PA, the EAP must also be properly estimated. This task would require a dense sampling of the Cartesian q-space. Alternatively, more efficient techniques have been proposed in the last decade. Even so, all of them imply acquiring a large number of diffusion gradients with different b-values and long processing times.\n\nIn this work, we propose an alternative implementation to drastically reduce the number of samples needed, as well as boosting the estimation procedure. We avoid the calculation of the whole EAP by assuming that the diffusion anisotropy is roughly independent from the radial direction. With such an assumption, we achieve a closed-form expression for a measure similar to the PA but using information from one single shell: the Apparent Propagator Anisotropy (APA). The new measure remains compatible with standard acquisition protocols commonly used for HARDI (based on just one b-value). The intention of the APA is not to exactly replicate the PA but inferring microstructural information with comparable discrimination power as the PA but using a reduced amount of data.\n\nWe report extensive results showing that the proposed measures present a robust behavior in clinical studies and they are computationally efficient and robust when compared with PA and other anisotropy measures.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Microstructure Diffusion Scalar Measures from Reduced MRI Acquisitions
Santiago Aja‐Fernández, Rodrigo de Luis-Garcı́a, … Antonio Tristán‐Vega·PLoS ONEPeer-reviewed·Mar 9, 2020
- Anisotropy Measure from Three Diffusion-Encoding Gradient Directions
Santiago Aja‐Fernández, Guillem París, … Antonio Tristán‐Vega·Magnetic Resonance ImagingPeer-reviewed·Feb 2, 2022
- A framework for spatial normalization and voxelwise analysis of diffusion propagators in multiple MAP-MRI data sets
Alexandru V. Avram, Adam S. Bernstein, … Peter J. Basser·bioRxiv·Jul 9, 2019
- Improving spatial normalization of brain diffusion MRI to measure longitudinal changes of tissue microstructure in the cortex and white matter.
Florencia Jacobacci, Jorge Jovicich, … Valeria Della‐Maggiore·Journal of Magnetic Resonance ImagingPeer-reviewed·Feb 14, 2020
- Computing the Orientational-Average of Diffusion-Weighted MRI Signals: A Comparison of Different Techniques
Maryam Afzali, Hans E. Knutsson, … Derek Kenton Jones·Scientific ReportsPeer-reviewed·Jul 12, 2021
- Novel Pore Size-Controlled, Susceptibility Matched, 3D-Printed MRI Phantoms