bioRxivBioengineering
A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress
M. Dabaghi, N. Rochow, N. Saraei, G. Fusch, S. Monkman, K. Da, A. Shahin Shamsabadi, J. L. Brash, D. Predescu, K. Delaney, C. Fusch, P. R. Selvaganapathy
Abstract
Premature neonates suffer from respiratory morbidity as their lungs are immature and current supportive treatment such as mechanical ventilation or extracorporeal membrane oxygenation (ECMO) cause iatrogenic injuries. A non-invasive and biomimetic concept known as the "artificial placenta" would be beneficial to overcome complications associated with the current respiratory support of preterm infants. Here, a pumpless oxygenator connected to the systemic circulation supports the lung function to relieve respiratory distress. In this paper, we demonstrate the first successful operation of a microfluidic, artificial placenta type neonatal lung assist device (LAD) on a newborn piglet model which is the closest representation of preterm human infants. This LAD has high oxygenation capability in both pure oxygen and room air as the sweep gas. It was able to relieve the respiratory distress that the newborn piglet was put under during experimentation, repeatedly and over significant duration of time. These findings indicate that this LAD has potential application as a biomimetic artificial placenta to support respiratory needs of preterm neonates.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A Rigid Parallel-Plate Artificial Placenta Oxygenator with a Hemocompatible Blood Flow Path
D. G. Blauvelt, N. C. Higgins, … S. Roy·bioRxiv·Aug 23, 2022
- Aeration Strategy at Birth Does Not Impact Carotid Blood Flow and Oxygen Delivery in Preterm Lambs
- The Effect of Ex-vivo Gravid Uterine Support on Umbilical Vessel Flow Velocities and Ductus Arteriosus Patency
Jennifer M Schuh, Araceli A. Morelos, … Jose H. Salazar·bioRxiv·Mar 14, 2025
- Effect of percutaneous ventricular assisted device on post-cardiac arrest myocardial dysfunction in swine model with prolonged cardiac arrest
T. Nakashima, M. H. Tiba, … R. W. Neumar·ResuscitationPeer-reviewed·Dec 1, 2023
- Reverse Pneumatic Artificial Muscles for Application in Low-Cost Artificial Respirators
S. Mirvakili, D. Sim, R. Langer·bioRxiv·May 20, 2020
- Effects of sustained inflation pressure during neonatal cardiopulmonary resuscitation of asphyxiated piglets
G.-H. Shim, S. Y. Kim, … G. M. Schmölzer·PLOS ONEPeer-reviewed·Jun 23, 2020