bioRxivBioengineeringPreprint
Towards robust, unobtrusive sensing of respiration using ultra-wideband impulse radar for the care of people living with dementia
Abstract
The unobtrusive monitoring of vital signals and behaviour can be used to gather intelligence to support the care of people living with dementia. This can provide insights into the persons wellbeing and the neurogenerative process, as well as enable them to continue to live safely at home, thereby improving their quality of life. Within this context, this study investigated the deployability of non-contact respiration rate (RR) measurement based on an Ultra-Wideband (UWB) radar System-on-Chip (SoC). An algorithm was developed to simultaneously and continuously extract the respiration signal, together with the confidence level of the respiration signal and the target position, without needing any prior calibration. The radar-measured RR results were compared to the RR results obtained from a ground truth measure based on the breathing sound, and the error rates were within 8% with a mean value of 2.4%. The target localisation results match to the radar-to-chest distances with a mean error rate of 5.4%. The tested measurement range was up to 5m. The results suggest that the algorithm could perform sufficiently well in non-contact stationary respiration rate detection.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Towards Continuous Home Monitoring for Dementia: A Real-Time mmWave Radar Framework for Activity Classification and Tracking
Ziwei Chen, Charalambos Hadjipanayi, … Timothy G. Constandinou·bioRxiv·May 8, 2026
- A Reusable Non-Adhesive Chest-Wall Acoustic Wearable Estimates Respiratory Rate During Rest and Exercise
Lisa Haxel, Antonia Schroff, … John W. Dickinson·bioRxiv·Jun 19, 2026
- Non-contact respiratory measurements of outdoor-housed rhesus macaques (Macaca mulatta) using millimeter-wave radars
T. Minami, D. Sanematsu, … M. Myowa·bioRxiv·Oct 11, 2023
- Capturing gait parameters during asymmetric overground walking using ultra-wideband radars: A preliminary study
Charalambos Hadjipanayi, Maowen Yin, Timothy G. Constandinou·Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)Peer-reviewed·Jul 15, 2024
- DBD-RCO: Derivative Based Detection And Reverse Combinatorial Optimization To Improve Heart Beat Detection For Wearable Devices
Andrea Bizzego, Cesare Furlanello·bioRxiv·Mar 21, 2017
- Robust and Remote Measurement of Heart Rate Based on A Surveillance Camera