PLoS ONEMicrobiologyPeer-reviewed journal article
OPTIMIZATION OF DRIED BLOOD SPOT ASSAYS FOR HEPATITIS B VIRUS SURFACE ANTIBODY QUANTIFICATION
Patience C. MotshosiiD, Bonolo Bonita PhiniusiD, Mosimanegape JongmaniD, Kabo BarutiiD, Lynnette N. BhebheiD, Graceful MulengaiD, Wonderful Tatenda ChogaiD, Sikhulile M. MoyoiD, Simani GaseitsiweiD, Motswedi AndersoniD
- Citations
- 1
- FWCI
- 0.33
- Field percentile
- top 50%
Abstract
Dried blood spot (DBS) cards can be used as an alternative sample collection method to plasma, however, there is no optimized elution protocol for DBS cards specifically for hepatitis B surface antibody (anti-HBs) testing. The study aimed to develop a DBS elution protocol for anti-HBs quantification. Our study sought to determine the ideal phosphate-buffered saline (PBS) buffer volume to use by comparing three PBS volumes (300uL, 450uL, and 500uL), and the optimal time to agitate DBS discs on a plate shaker (1hr, 2hrs, 3hrs, and 4hrs) to yield DBS anti-HBs concentrations that are comparable to corresponding plasma anti-HBs concentrations. The optimal DBS storage temperature (25{degrees}C, -20{degrees}C, and -80{degrees}C) was investigated to determine the ideal longterm storage temperature of the cards. Residual samples were used for optimization (2019-2021). A total of 50 DBS-plasma pairs was used throughout the study, with plasma anti-HBs concentrations being used as the golden standard to compare. The analysis of results was carried out by determining the p-values of the Wilcoxon sign rank. A two-way analysis of variance (ANOVA) was also performed to determine the impact of PBS elution volumes, elution time, and storage temperature on the anti-HBs concentration of DBS samples on STATA Version 15.0. No statistically significant difference between the DBS-plasma anti-HBs pairs was observed when using 450 or 500uL of PBS buffer and when samples were agitated for 3 hours (p=0.594, p=0.499 respectively). The optimal storage temperature for DBS cards was 25{degrees}C because the results showed no statistically significant difference between DBS-plasma anti-HBs titers (p=0.594). The two-way ANOVA analysis showed that elution volumes and time had no statistically significant impact on the DBS anti-HBs concentrations, p=0.948 and p=0.381 respectively. Storage temperature had a statistically significant impact on the DBS anti-HBs concentrations, p=0.002. The optimized DBS elution protocol for anti-HBs quantification will help monitor vaccine efficacy in infants due to the low sample volumes required compared to plasma and also can be used for anti-HBs testing in resource-limited areas around the country.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluation of DNA extracted from blood filter spots and eluates processed for enzyme linked immunosorbent assay (ELISA)
Mark A. Xatse, Jewelna Akorli, … Michael D. Wilson·bioRxiv·Feb 4, 2019
- Electricity-free nucleic acid extraction method from dried blood spots on filter paper for point-of-care diagnostics
Kenny Malpartida-Cardenas, Jake Baum, … Jesús Rodríguez-Manzano·bioRxiv·Jul 28, 2022
- Quantitating SARS-CoV-2 Neutralizing Antibodies from Human Dried Blood Spots
K. Berman, G. Van Slyke, … N. J. MANTIS·bioRxiv·Mar 18, 2024
- Short-term stabilities of 21 amino acids in dried blood spots
J. Han, R. Higgins, … C. H. Borchers·bioRxiv·Sep 30, 2017
- Systematic review of the validity of the hepatitis B virus detection tests in blood banks from 2000 to 2018.
C. P. Orrego-Marin, J. A. Cardona-Arias, … J. C. Zapata·bioRxiv·Apr 17, 2020
- Whatman FTA(R) cards versus plasma specimens for the quantitation of HIV-1 RNA using two Real-Time PCR assays
Abdourahamane Yacouba, Malika Congo-Ouédraogo, … Lassana Sangaré·Access MicrobiologyPeer-reviewed·Jun 17, 2020