Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement
J. A. Gustafson, S. P. Mell, B. Levine, R. Pourzal, H. J. Lundberg
Abstract
Implant failure due to fretting corrosion at the head-stem modular junction is an increasing problem in modular total hip arthroplasty. The effect of varying microgroove topography on modular junction contact mechanics has not been well characterized. The aim of this work was to employ a novel, microgrooved finite element (FEA) model of the hip taper interface and assess the role of microgroove geometry and taper mismatch angle on the modular junction mechanics during assembly. A two-dimensional, axisymmetric FEA model was created using a modern 12/14 taper design of a CoCrMo femoral head taper and Ti6Al4V stem taper. Microgrooves were modelled at the contacting interface of the tapers and varied based on height and spacing measurements obtained from a repository of measured retrievals. Additionally, taper angular mismatch between the head and stem was varied to simulate proximal- and distal-locked engagement. Forty simulations were conducted to parametrically evaluate the effects of microgroove surface topography and angular mismatch on predicted contact area, contact pressure, and equivalent plastic strain. Multiple linear regression analysis was highly significant (p 0.74) for all outcome variables. The regression analysis identified microgroove geometry on the head taper to have the greatest influence on modular junction contact mechanics. Additionally, there was a significant second order relationship between both peak contact pressure (p < 0.001) and plastic strain (p < 0.001) with taper mismatch angle. These modeling techniques will be used to identify the implant parameters that maximize taper interference strength via large in-silico parametric studies.
02 /Specification & Classification
Click any tag to browse matching papers- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Strategic Debulking of the Femoral Stem Promotes Load Sharing Through Controlled Flexural Rigidity of the Implant Wall: Optimization of Design by Finite Element Analysis.
G. Sunavala-Dossabhoy, B. M. Saba, K. J. McCarthy·bioRxiv·Jan 12, 2024
- Conformable and robust force sensors to enable precision joint replacement surgery
L. Ives, A. Pace, … S. Kar-Narayan·bioRxiv·Aug 19, 2021
- Embedding wear assessment in musculoskeletal simulation: A proof-of-concept application to total hip arthroplasty
Andrea Di Pietro, Lorenza Mattei, Francesca Di Puccio·Applied SciencesPeer-reviewed·Oct 2, 2026
- Why detailed modelling matters in the pre-clinical evaluation of temporomandibular joint implants
Girish Chandra, Rajdeep Ghosh, … Kaushik Mukherjee·bioRxiv·Apr 28, 2025
- Microgradients in porosity and canal diameter in femur bone
Xiao Zhao, Xiaojun Yu, … Cevat Erişken·bioRxiv·Dec 19, 2025
- Simulating Contact Using the Elastic Foundation Algorithm in OpenSim
M. W. Hast, B. G. Hanson, J. R. Baxter·bioRxiv·May 10, 2018