bioRxivBioengineeringPreprint
Conformable and robust force sensors to enable precision joint replacement surgery
L. Ives, A. Pace, F. Bor, Q. Jing, T. Wade, J. Cama, V. Khanduja, S. Kar-Narayan
Abstract
Balancing forces within weight-bearing joints such as the hip during joint replacement surgeries is essential for implant longevity. Minimising implant failure is vital to improve patient wellbeing and alleviate pressure on healthcare systems. With improvements in surgery, hip replacement patients are now often younger and more active than in previous generations, and their implants correspondingly need to survive higher stresses. However, force balancing currently depends entirely on surgical skill: no sensors can provide quantitative force feedback within the hip joints small, complex geometry. Here, we solve this unmet clinical need by presenting a thin and conformable microfluidic force sensor, which is compatible with the standard surgical process. We optimised the design using finite element modelling, then incorporated and calibrated our sensor in a model hip implant. Using a bespoke testing rig, we demonstrated high sensitivity at typical forces experienced during hip replacements. We anticipate that these sensors will aid implant positioning, increasing the lifetime of hip replacements, and represent a powerful new surgical tool for a range of orthopaedic procedures where force balancing is crucial.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Measuring Orthopedic Plate Strain to Track Bone Healing Using a Fluidic Sensor Read via Plain Radiography
A. Rajamanthrilage, M. Arifuzzaman, … J. N. Anker·bioRxiv·Aug 27, 2020
- Wearable Estimation of Knee Joint Contact Forces: SiMPLeSENSE, a Simulated-IMU Pipeline Validated Against In Vivo Loads
Alessandro Castellaz, Sabrina Hörmann, … Frank Wouda·bioRxiv·Nov 3, 2026
- Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement
J. A. Gustafson, S. P. Mell, … H. J. Lundberg·bioRxiv·Jan 20, 2022
- Closed-loop feedback control for microfluidic systems through automated capacitive fluid height sensing
L. R. Soenksen, T. Kassis, … D. L. Trumper·bioRxiv·Jan 12, 2018
- Embedding wear assessment in musculoskeletal simulation: A proof-of-concept application to total hip arthroplasty
Andrea Di Pietro, Lorenza Mattei, Francesca Di Puccio·Applied SciencesPeer-reviewed·Oct 2, 2026
- AFM Microfluidic Cantilevers as Weight Sensors for Single Cell Mass Measurements
C.-c. Chien, J. Jiang, … A. Gaitas·bioRxiv·Feb 21, 2022