Neurosurgical FOCUSNeurosciencePeer-reviewed journal article
Implantation technique, safety and complications of robot-assisted stereoelectroencephalography exploration of the limbic thalamus in human focal epilepsy
Ganne ChaitanyaiD, Andrew K. Romeo, Adeel IlyasiD, Auriana B. Irannejad, Emília Tóth, Galal ElsayediD, J. Nicole BentleyiD, Kristen Owen RileyiD, Sandipan Bankim Behari PatiiD
Abstract
IntroductionDespite numerous imaging studies highlighting the importance of thalamus in surgical prognosis, human electrophysiological studies involving the limbic thalamic nuclei are limited. The objective of this study was to evaluate the safety and accuracy of robot-assisted stereotactic electrode placement in the limbic thalamic nuclei in patients with suspected temporal lobe epilepsy (TLE). MethodsAfter obtaining informed consent, 24 adults with drug-resistant suspected TLE undergoing Stereo-EEG evaluation were enrolled in this prospective study. The trajectory of one electrode planned for clinical sampling the operculo-insular cortex was modified to extend to the thalamus, thereby preventing the need for additional electrode placement for research. The anterior thalamus (ANT) (N=13) and the medial group of thalamic nuclei (MED) (N=11), including mediodorsal (MD) and centromedian (CeM) were targeted. The post-implantation CT was co-registered to the pre-operative MRI, and Morels thalamic atlas was used to confirm the accuracy of implantation. ResultsTen out of 13 (77%) in the ANT group and 10 out of 11 patients (90%) in the medial group had electrodes accurately placed in the thalamic nuclei. None of the patients had a thalamic hemorrhage. However, trace asymptomatic hemorrhages at the cortical level entry site were noted in 20.8% of patients and they did not require additional surgical intervention. SEEG data from all the patients were interpretable and analyzable. The trajectories for the ANT implant differed slightly from the medial group at the entry point i.e., precentral gyrus in the former and postcentral gyrus in the latter. ConclusionsUsing judiciously planned robot-assisted SEEG, we demonstrate the safety of electrophysiological sampling from various thalamic nuclei for research recordings, presenting a technique that avoids implanting additional depth electrodes, or comprising clinical care. With these results, we propose that if patients are fully informed of the risks involved, there are potential benefits of gaining mechanistic insights to seizure genesis, which may help to develop neuromodulation therapies.
- Citations
- 60
- FWCI
- 5.11
- Field percentile
- top 4%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multisite Thalamic Recordings to Characterize Seizure Propagation in the Human Brain
Teresa Q. Wu, Neda Kaboodvand, … Josef Parvizi·BrainPeer-reviewed·May 3, 2023
- Thalamic Interictal Epileptic and Non-Epileptic Events during NREM Sleep in Patients with Focal Epilepsy: a Stereo-EEG Study
Hongyi Ye, Kassem Jaber, … Birgit Frauscher·EBioMedicinePeer-reviewed·May 14, 2026
- Ictal recruitment of anterior nucleus of thalamus in human focal epilepsy
Emília Tóth, Ganne Chaitanya, … Sandipan Bankim Behari Pati·bioRxiv·Oct 1, 2019
- Evaluating Invasive EEG Implantations in Medically Refractory Epilepsy with Functional Scalp EEG Recordings and Structural Imaging Data
Anil K. Palepu, Adam Li, … Sridevi V. Sarma·bioRxiv·Feb 19, 2019
- Early Ictal Recruitment of Midline Thalamus in Mesial Temporal Lobe Epilepsy
Andrew K. Romeo, Alexandra T. Issa Roach, … Sandipan Bankim Behari Pati·Annals of Clinical and Translational NeurologyPeer-reviewed·Jul 5, 2019
- Fully Automated and Noise-Robust SEEG Electrode Localization under Practical Clinical Conditions
C. L. Philip Chen, Long Zhang, Pei Feng Tong·bioRxiv·Feb 13, 2026