Journal of Applied BiomedicineNeurosciencePeer-reviewed journal article
Low-Frequency Textured Gabor Flicker Enhances Neural Entrainment and Visual Comfort for Brain-Computer Interface Control
- Citations
- 1
- FWCI
- 4.18
- Field percentile
- top 6%
Abstract
Steady-state visual evoked potentials (SSVEPs) are widely used in cognitive neuroscience and brain-computer interfaces (BCIs), but the visual discomfort induced by repetitive luminance flicker limits their usability, particularly in multi-target settings due to strong peripheral distraction. Textured flicker composed of Gabor patches has been proposed as a more comfortable alternative, but its suitability for SSVEP paradigms and its frequency-dependent impact on neural entrainment remain unclear. Here, we directly compared textured Gabor-based flicker and classical luminance flicker using a frequency sweep followed by a multi-class SSVEP BCI task. In Session 1 (N=24), we measured SSVEP signal-to-noise ratio (SNR), inter-trial coherence (ITC), and subjective comfort across 13 stimulation frequencies (3-18Hz). Gabor-based textures elicited higher SNR and ITC than plain flicker at low frequencies (3-9Hz), whereas plain flicker produced stronger and more phase-consistent responses at higher frequencies (12-18Hz), revealing a robust crossover in entrainment. Across almost all frequencies, Gabor stimuli were rated as more comfortable. Based on these results, we defined a low-frequency Gabor-optimized band (5-7Hz) and a higher plain-optimized band (14-16Hz). In Session 2 (N=18), these bands were used in a five-class offline SSVEP BCI. Classification accuracy was highest (Gabor: 95.7% at 5-7Hz; plain: 98.1% at 14-16Hz) when each stimulus type was used in its optimal band and decreased markedly when stimulus type and frequency band were mismatched. Gabor stimuli were consistently rated as more comfortable and nearly imperceptible in peripheral vision. Together, these findings establish textured Gabor flicker as a comfortable and effective alternative to luminance flicker for low-frequency SSVEP paradigms.
- assay: electronic health records
- research focus: benchmarking
- research focus: drug response / drug discovery
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Individualized Gabor Flicker for Well-Tolerated Neural Entrainment During Working Memory
Clément Blanc, Frédéric Dehais, Sébastien Scannella·bioRxiv·Oct 8, 2026
- Leveraging Grating-Based Flickers: A Leap Toward Practical, Visually Comfortable, and High-Performance Dry EEG Code-VEP BCI
Frédéric Dehais, Kalou Cabrera Castillos, … Pierre Clisson·bioRxiv·Jul 17, 2024
- Frequency-tagging of spatial attention using periliminal flickers
Simon Ladouce, Frédéric Dehais·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Neural entrainment induced by periodic audiovisual stimulation: A large-sample EEG study
Joel Frohlich, Ninette Simonian, … Nicco Reggente·bioRxiv·Oct 25, 2023
- A User-Friendly Ear-EEG-Based Brain-Computer Interface Using Text Sequence Stimulation
Xiaoyang Li, Zhuoran Xu, … Xiaorong Gao·Journal of Applied BiomedicinePeer-reviewed·Oct 1, 2026
- Attention differentially modulates the amplitude of resonance frequencies in the visual cortex
Rasa Gulbinaite, Diane H. M. Roozendaal, Rufin Vanrullen A·bioRxiv·Jan 11, 2019