Low-Cost Real-Time Fiber-Optic Distance Sensing for OPM-based Biomagnetic Measurements
- Citations
- 0
Abstract
Background: Accurate tracking of the distance between magnetic sensors and biological tissue is particularly relevant to biomagnetic measurements in which stable wearable sensor configurations are not feasible, such as optically pumped magnetometer-based magnetomyography (OPM-MMG). In these measurements, movement-induced changes in source-to-sensor geometry can affect the recorded signal nonlinearly and complicate motion artifact control. Because components used near optically pumped magnetometers must be nonmagnetic to minimize magnetic interference, a compact, nonmagnetic method is needed for real-time monitoring of sensor-to-surface distance. Methods: Low-cost, nonmagnetic polymer fiber sensors (Keyence FS-N11MN with FU-6F fibers) were evaluated for real-time distance measurement using a fully automated linear stage over a range of 0-30 mm and at controlled incidence angles from 50 to 90 degrees. The sensors generated analog output voltages from 1 to 5 V, sampled at 2048 Hz, with a response time of 16 ms. Custom scripts were used for signal averaging, noise estimation, uncertainty weighting, calibration, and distance reconstruction. Results: Voltage decreased nonlinearly with increasing distance. For the pooled data obtained at 80 and 90 degrees, weighted Hill1 fits over 0-10 mm and 0-30 mm yielded adjusted R-squared values greater than 0.9990. Across the five sensors, the mean absolute reconstruction error was 0.0282 mm when both calibration and evaluation were restricted to 0-10 mm, and 0.1310 mm when calibration over 0-30 mm was evaluated over 10-30 mm. Periodic modulation was observed beyond 10 mm, remained present when Sensor 1 was operated independently, and was consistent with the discrete internal signal levels of the sensor. Conclusion: Low-cost, nonmagnetic polymer fiber sensing may provide a compact, real-time method for monitoring sensor-to-surface distance over 0-10 mm in optically pumped magnetometer-based biomagnetic measurements. Extension across the full 0-30 mm range will require range-specific calibration and further validation using skin-facing surfaces.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Discrimination of finger movements by magnetomyography with optically pumped magnetometers
Antonino Greco, Sangyeob Baek, … Markus Siegel·Scientific ReportsPeer-reviewed·Dec 13, 2023
- Inferring laminar origins of MEG signals with optically pumped magnetometers (OPMs): a simulation study
Saskia Helbling·Imaging NeurosciencePeer-reviewed·Dec 6, 2024
- Portable quantum-sensor magnetomyography decodes fine hand movements
Antonino Greco, Thomas Middelmann, … Markus Siegel·bioRxiv·Dec 25, 2025
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Pragmatic spatial sampling for wearable MEG arrays
Tim M. Tierney, Stephanie Mellor, … Gareth Robert Barnes·Scientific ReportsPeer-reviewed·Dec 10, 2020
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024