NeuroImageNeurosciencePeer-reviewed journal article
Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Abstract
Optically-pumped magnetometers (OPMs) have recently reached sensitivity levels required for magnetoencephalogra-phy (MEG). OPMs do not need cryogenics and can thus be placed within millimetres from the scalp into an array that adapts to the invidual head size and shape, thereby reducing the distance from cortical sources to the sensors. Here, we quantified the improvement in recording MEG with hypothetical on-scalp OPM arrays compared to a 306-channel state-of-the-art SQUID array (102 magnetometers and 204 planar gradiometers).\n\nWe simulated OPM arrays that measured either normal (nOPM; 102 sensors), tangential (tOPM; 204 sensors), or all components (aOPM; 306 sensors) of the magnetic field. We built forward models based on magnetic resonance images of 10 adult heads; we employed a three-compartment boundary element model and distributed current dipoles evenly across the cortical mantle.\n\nCompared to the SQUID magnetometers, nOPM and tOPM yielded 7.5 and 5.3 times higher signal power, while the correlations between the field patterns of source dipoles were reduced by factors of 2.8 and 3.6, respectively. Values of the field-pattern correlations were similar across nOPM, tOPM and SQUID gradiometers. Volume currents reduced the signals of primary currents on average by 10%, 72% and 15% in nOPM, tOPM and SQUID magnetometers, respectively. The information capacities of the OPM arrays were clearly higher than that of the SQUID array. The dipole-localization accuracies of the arrays were similar while the minimum-norm-based point-spread functions were on average 2.4 and 2.5 times more spread for the SQUID array compared to nOPM and tOPM arrays, respectively.
- Citations
- 295
- FWCI
- 7.72
- Field percentile
- top 2%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Mainak Jas, Teppei Matsubara, … Seppo P. Ahlfors·bioRxiv·Aug 21, 2026
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- Requirements for coregistration accuracy in on-scalp MEG
Rasmus Zetter, Joonas Iivanainen, … Lauri T. Parkkonen·Brain TopographyPeer-reviewed·Jun 22, 2018
- Detection of the 40-Hz Auditory Steady-state Response with Optically Pumped Magnetometers
Kyung‐min An, Jeong Hyun Shim, … Kiwoong Kim·Scientific ReportsPeer-reviewed·Oct 26, 2022
- Measurement Equivalence of On-Scalp OPM-MEG and Cryogenic MEG for Auditory and Somatosensory Cortical Mapping Across Development
William C. Gaetz, George C. O’Neill, … Orang Alem·bioRxiv·Jul 20, 2026
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022