Scientific ReportsNeurosciencePeer-reviewed journal article
Pragmatic spatial sampling for wearable MEG arrays
Tim M. TierneyiD, Stephanie MelloriD, George C. O’NeilliD, Niall HolmesiD, Elena BotoiD, Gillian RobertsiD, Ryan M. HilliD, James LeggettiD, Richard W BowtelliD, Matthew J. BrookesiD, Gareth Robert BarnesiD
Abstract
Several new technologies have recently emerged promising new MEG systems in which the sensors can be placed close to the scalp. One such technology, Optically Pumped Magnetometry MEG (OP-MEG) allows for a scalp mounted flexible system that provides field measurements within mm of the scalp surface. A question that arises in developing on-scalp systems, such as OP-MEG scanners, is: how many sensors are necessary to achieve adequate performance/spatial discrimination? There are many factors to consider in answering this question such as the signal to noise ratio (SNR), the locations and depths of the sources of interest, the density of spatial sampling, sensor gain errors (due to interference, subject movement, cross-talk, etc.) and, of course, the desired spatial discrimination. In this paper, we provide simulations which show the impact these factors have on designing sensor arrays for wearable MEG. While OP-MEG has the potential to provide high information content at dense spatial samplings, we find that adequate spatial discrimination of sources (<1cm) can be achieved with relatively few sensors (<100) at coarse spatial samplings (~30mm) at high SNR. Comparable discrimination for traditional cryogenic systems require far more channels by these same metrics. Finally we show that sensor gain errors have the greatest impact on discrimination between deep sources at high SNR.
- Citations
- 48
- FWCI
- 2.54
- Field percentile
- top 9%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Requirements for coregistration accuracy in on-scalp MEG
Rasmus Zetter, Joonas Iivanainen, … Lauri T. Parkkonen·Brain TopographyPeer-reviewed·Jun 22, 2018
- Modular Arrays for High Precision Wearable MEG
Nicholas Alexander, Alberto Mariola, … Martina F. Callaghan·bioRxiv·Aug 24, 2026
- Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Mainak Jas, Teppei Matsubara, … Seppo P. Ahlfors·bioRxiv·Aug 21, 2026
- Inferring laminar origins of MEG signals with optically pumped magnetometers (OPMs): a simulation study
Saskia Helbling·Imaging NeurosciencePeer-reviewed·Dec 6, 2024
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024