Validation of deep learning enabled web based and smartphone optimized application RadAnalyzer to measure vertebral heart size and vertebral left atrial size in dogs
Sonya G. GordoniD, Tomas ReyesiD, Tabitha Baibos-Reyes, Katharine Tess Sykes, Sukjung Lim, Alice H. WatsoniD
Abstract
BackgroundObjective radiographic measures of heart size including vertebral heart size (VHS) and vertebral left atrial size (VLAS) are associated with inter and intra-observer variability when measured by humans. Artificial intelligence (AI) tools including RadAnalyzer are available to measure VHS and VLAS. ObjectivesCompare VHS and VLAS measurements made by web based and smartphone optimized deep learning enabled program, RadAnalyzer, to a trained observer. Animals1058 client-owned dogs, across 80 breeds with a variety of heart sizes and thoracic confirmations. MethodsRetrospective, single center, method comparison study. Pearsons correlation, Bland-Altman plots and Passing-Bablok regression were used to assess agreement. ResultsRadAnalyzer measurements of VHS and VLAS correlated well with the human observers modified measurements (r=0.917 and r=0.873 respectively) and had small mean biases (0.002 and 0.007 vertebrae respectively). Conclusions and clinical importanceRadAnalyzer had clinically insignificant magnitude differences in measurement of VHS and VLAS when compared to a human observer and can therefore be used to assist veterinarians with measuring VHS and VLAS on right lateral radiographs in dogs of all sizes. Future studies comparing AI derived radiographic measures with echocardiographic measures of cardiac size are required.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 1.95
- Field percentile
- top 19%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Validation of deep learning enabled software MetronMind to measure vertebral heart size and vertebral left atrial size in dogs
Katharine Tess Sykes, Sonya G. Gordon, … Alice H. Watson·PLoS ONEPeer-reviewed·Jun 30, 2026
- Assessing the Accuracy of a Smart Collar for Dogs: Predictive Performance for Heart and Breathing Rates on a Large Scale Dataset
H. Jarkoff, G. Lorre, E. Humbert·bioRxiv·Jun 9, 2023
- Infarctsize-AI: an efficient infarct size image analysis tool for small rodent myocardial infarction studies
Csenger Kovácsházi, Dóra Kapui, … Zoltán Giricz·bioRxiv·Nov 18, 2025
- Convolutional neural networks for automated CMR image segmentation in rats with myocardial infarcts
A. Gondova, M. Zurek, … E. Watson·bioRxiv·Dec 1, 2020
- Automated Detection and Diameter Estimation for Mouse Mesenteric Artery using Semantic Segmentation
A. Higaki, A. U. M. Mahmoud, … E. L. Schiffrin·bioRxiv·Oct 28, 2020
- Automated Ventricle Assessment via Three-dimensional Anatomical Reconstruction (AVA-TAR): a computational toolkit for autonomous lateral ventricle assessment in preclinical hydrocephalus models